View Single Post
  #61   Report Post  
Posted to sci.electronics.repair,rec.radio.amateur.antenna,sci.electronics.design
Jeff Liebermann Jeff Liebermann is offline
external usenet poster
 
Posts: 4,045
Default Increasing Cable TV signal strength

On Fri, 10 Feb 2012 08:38:44 -0800, Jeff Liebermann
wrote:

I think the official minimum pull test is 55 lbs, but
I'm too lazy to Google for it now.


40 lbs outdoors, 30 lbs indoors.

http://www.scte.org/documents/pdf/standards/SCTE_124_2011.pdf
6.2.2
Axial Pull Force: The male “F” pin type connector, when
attached to cables manufactured to SCTE approved standards,
shall withstand a minimum axial pull force of 40 lbs for
outdoor and 30 lbs for indoor applications when tested
per ANSI/SCTE 99 2009, Test Method For Axial Pull
Connector/Drop Cable.

I doubt that the crimp connectors could pass the test.

--
# Jeff Liebermann 150 Felker St #D Santa Cruz CA 95060
# 831-336-2558
# http://802.11junk.com
#
http://www.LearnByDestroying.com AE6KS