"Chris F." wrote in message
...
This 2001 model projection set has a tough problem to track down, so I'm
hoping someone can give me some advice. Fuse F850 (5A), in the power
supply, will blow at random intervals - sometimes when trying to power up,
or the set might run fine for hours, days, or even weeks. Just thought I'd
check for any known issues with this set, before attempting what could be
a long and frustrating job.



I've come across equipment before that has the wrong fuse specified. For
various reasons the manufacturer uprated it later on. And of course, the
manufacturer might not be in a hurry to point out its mistake .......