View Single Post
  #4   Report Post  
Posted to alt.home.repair
Speedy Jim[_2_] Speedy Jim[_2_] is offline
external usenet poster
 
Posts: 205
Default Replace toilet base

wrote:

Thanks,

For the closet flange it looks similiar to what I have with the tube
part that goes into the drainage at 4 inches wide and the whole part
is 3.5 inches height.
Do I need any silicone when I put it in? And if I need the tube part
that connects to drainage what kind of silicone do I use?



The first one with the rubber seal at the bottom doesn't need any
sealant.

The plastic fittings are normally "solvent welded" using a special
glue. For the black plastic, it is ABS cement. Silicone sealant (RTV)
*could* be used, but it's not a recognized method.

The flange should be anchored to the floor, if possible.