View Single Post
  #3   Report Post  
Posted to uk.d-i-y
Dave Plowman (News)
 
Posts: n/a
Default Low Voltage Lighting transformer problem

In article ,
Ben Mack wrote:
I've installed some 12V halogen lights in some shelves, such that I have
to mount the transformer remotely. I used 3m of normal 1.5mm^2 lighting
cable to connect the transformer to the lights, having calculated a
300mV drop across the cable (30mV/A/m x 3.3A x 3m)


However in practise I'm losing around 6V in the cable, and have
discovered that the transformer output is 125kHz, not 50Hz, explaining
the bad attenuation in the cable


So my question is - do all compact dimmable 12V transformers have high
frequency outputs?


I don't have space for an old-fashioned 50Hz transformer


TLC have a cable calculator for LV lamps. Dunno if it will help with your
problem.

http://www.tlc-direct.co.uk/Technica...ltageDrop.html

--
*You sound reasonable......time to up my medication

Dave Plowman London SW
To e-mail, change noise into sound.