Johnboy
 
Posts: n/a
Default QUESTION: Dust collection plumbing. PVC or metal duct?

I finally retired my shop vac, always had to wear ear muffs. Bought a
Jet DC, the dc 650. Wow! So quite and it was interesting that when I
hooked it up to my table saw, I hadn't cut any wood but it had much
more power than the shop vac. I pulled the table insert, looked at the
amount of dust inside, then turned on the DC and couldn't believe the
dust that the shop vac wouldn't get disappear with the Jet.
SO, I now need to hook up my vents. I've read on the net PVC vs.
metal. It's like cars, everyone has thier own opinion. From what I've
read, I'm leaning towards metal. Will go shopping and compare prices.
I don't have that much to run in my basement shop.
Opinions?

  #2   Report Post  
Mike in Mystic
 
Posts: n/a
Default

Honestly, a 1 HP dust collector is underpowered to use on a central dust
collection system, except for extremely short runs. The way to get the most
efficient set up is to use a straight run along a wall, maybe 2-3' off the
floor (i.e. don't go vertical up and down from the ceiling). The best use
for this size is to actually wheel it from tool to tool, or use a length of
maybe 10' of flexible 4" hose.

I went up to a 2 HP unit, and use it with 5" PVC main line and 4" drops with
a total duct length of about 30' and it works o.k. I think the guys with
the cyclone dust collectors have better overall performance.

Anyway, I'm sure there's a way to set yours up to get best use - just don't
be surprised if you don't the same performance when you run it through a lot
of PVC as you did when directly hooked up to your tools.

BTW, you can see what I think about the duct material - PVC works great.
And, before you get inundated with warnings and scare-talk - it is a myth
about dust explosions in small woodworking shops (there has been MUCH
discussion about this, and even scientific testing - woodworking magazines
have run articles on it, etc. etc. - and all of them say the risk of
explosion is nearly infintesimal). You can ground the PVC if you want, but
that really isn't necessary either. Just be sure to avoid sucking up metal
bits (screws, nails, etc.) that might cause a spark if they hit the impeller
of your DC - THAT can start a fire in your dust bags/container.

Mike


"Johnboy" wrote in message
...
I finally retired my shop vac, always had to wear ear muffs. Bought a
Jet DC, the dc 650. Wow! So quite and it was interesting that when I
hooked it up to my table saw, I hadn't cut any wood but it had much
more power than the shop vac. I pulled the table insert, looked at the
amount of dust inside, then turned on the DC and couldn't believe the
dust that the shop vac wouldn't get disappear with the Jet.
SO, I now need to hook up my vents. I've read on the net PVC vs.
metal. It's like cars, everyone has thier own opinion. From what I've
read, I'm leaning towards metal. Will go shopping and compare prices.
I don't have that much to run in my basement shop.
Opinions?



  #3   Report Post  
Robbie
 
Posts: n/a
Default

In article ,
Johnboy wrote:

I finally retired my shop vac, always had to wear ear muffs. Bought a
Jet DC, the dc 650. Wow! So quite and it was interesting that when I
hooked it up to my table saw, I hadn't cut any wood but it had much
more power than the shop vac. I pulled the table insert, looked at the
amount of dust inside, then turned on the DC and couldn't believe the
dust that the shop vac wouldn't get disappear with the Jet.
SO, I now need to hook up my vents. I've read on the net PVC vs.
metal. It's like cars, everyone has thier own opinion. From what I've
read, I'm leaning towards metal. Will go shopping and compare prices.
I don't have that much to run in my basement shop.
Opinions?


You should always wear muffs whilst using power tools. Just because a
tool's acoustic output isn't 'obviously' offensive to the ear, doesn't
mean it isn't doing damage.
Use muffs because those plugs are not a good idea as they tend to ram
waxy sawdust into the ear canal during insertion.

JM2CW
  #4   Report Post  
Tom Veatch
 
Posts: n/a
Default

On Fri, 19 Nov 2004 12:18:47 -0600, Johnboy wrote:

I finally retired my shop vac, always had to wear ear muffs. Bought a
Jet DC, the dc 650. Wow! So quite and it was interesting that when I
hooked it up to my table saw, I hadn't cut any wood but it had much
more power than the shop vac. I pulled the table insert, looked at the
amount of dust inside, then turned on the DC and couldn't believe the
dust that the shop vac wouldn't get disappear with the Jet.
SO, I now need to hook up my vents. I've read on the net PVC vs.
metal. It's like cars, everyone has thier own opinion. From what I've
read, I'm leaning towards metal. Will go shopping and compare prices.
I don't have that much to run in my basement shop.
Opinions?



I am currently installing ducting for a cyclone. I'm using 6" PVC, ASTM-D2729,
also known as S&D. Much lighter than the Sched 40 stuff. According to Bill
Pentz's web site http://billpentz.com//woodworking/cyclone/index.cfm it's as
good or almost as good as the Spiral Wrap steel ducting. My cost comparisons
found that the locally purchased S&D PVC was about 1/4 the cost, overall, of the
SW steel, not considering shipping costs.

You don't say whether you're considering the SW steel or HVAC ducting. My
opinion is that you should read what Bill has to say about it before you write
any checks. He also has some things to say about desirable modifications to
commercially available DC units.

Tom Veatch
Wichita, KS USA
  #5   Report Post  
Old Nick
 
Posts: n/a
Default

On Fri, 19 Nov 2004 14:39:04 -0500, Robbie
vaguely proposed a theory
.......and in reply I say!:

remove ns from my header address to reply via email



Use muffs because those plugs are not a good idea as they tend to ram
waxy sawdust into the ear canal during insertion.


And your problem with _that_ is? GG

Seriously, it can be a problem. I use them a lot, because I need
hearing protection just about all the time, and muffs are a PITA. But
the wax problem is real.

Sorry...what did you say? G

************************************************** ***
Dogs are better than people.

People are better than dogs for only one purpose. And
then it's only half of ofthe people. And _then_ most
of them are only ordinary anyway. And then they have a
headache.........


  #6   Report Post  
Old Nick
 
Posts: n/a
Default

On Fri, 19 Nov 2004 18:40:08 GMT, "Mike in Mystic"
vaguely proposed a theory
.......and in reply I say!:

remove ns from my header address to reply via email

I did some quick plugging in to a little programme I have that does
air flows.

IIRC the 1HP units claim around 600CFM usually? I imagine that the
figure is quoted with NO pipe on the unit. It is complicated by the
need to push the air through the filters.

These may help. I am not sure of the _absolute_ meaning, as it its' a
complex system. Other may elucidate.

But larger pipe is good.

I _think_ that needing to use 2/3 HP to shove 600CFM through 4" pipe
means that power is _lost_ in the pipe, and will represent a dramatic
drop in performance of the DC, due to the fan's being only partially
efficient etc.

If you were using dead straight pipe, then
- 4" pipe up to 45ft long would need 2/3 HP.
- 6" pipe up to 45ft long would need about 1/10 HP.

So pipe diameter is dramatic on long runs.

I plugged in a couple of elbows:
4" pipe, power went from 2/3 HP to around 1.2HP, each elbow was
about .15 HP
6" pipe, power went from 1/10 HP to around 1/6 HP, each elbow was
about .03 HP

Again bigger pipe makes a huge difference.

Which is why this bit....

The way to get the most
efficient set up is to use a straight run along a wall, maybe 2-3' off the
floor (i.e. don't go vertical up and down from the ceiling).



The best use
for this size is to actually wheel it from tool to tool, or use a length of
maybe 10' of flexible 4" hose.


************************************************** ***
Dogs are better than people.

People are better than dogs for only one purpose. And
then it's only half of ofthe people. And _then_ most
of them are only ordinary anyway. And then they have a
headache.........
  #7   Report Post  
mac davis
 
Posts: n/a
Default

On Sat, 20 Nov 2004 09:45:25 +0800, Old Nick
wrote:

On Fri, 19 Nov 2004 18:40:08 GMT, "Mike in Mystic"
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

I did some quick plugging in to a little programme I have that does
air flows.

IIRC the 1HP units claim around 600CFM usually? I imagine that the
figure is quoted with NO pipe on the unit. It is complicated by the
need to push the air through the filters.

These may help. I am not sure of the _absolute_ meaning, as it its' a
complex system. Other may elucidate.

But larger pipe is good.

I _think_ that needing to use 2/3 HP to shove 600CFM through 4" pipe
means that power is _lost_ in the pipe, and will represent a dramatic
drop in performance of the DC, due to the fan's being only partially
efficient etc.

If you were using dead straight pipe, then
- 4" pipe up to 45ft long would need 2/3 HP.
- 6" pipe up to 45ft long would need about 1/10 HP.

So pipe diameter is dramatic on long runs.

I plugged in a couple of elbows:
4" pipe, power went from 2/3 HP to around 1.2HP, each elbow was
about .15 HP
6" pipe, power went from 1/10 HP to around 1/6 HP, each elbow was
about .03 HP

Again bigger pipe makes a huge difference.

interesting, nick.. and it makes sense..

I guess the elbow thing is sort of a "damned if you do, damned if you
don't" kind of thing, especially when applied to a cyclone..
I wouldn't want to use my DC without it, but among other issues,
you're adding at least 2 elbows to make it work..

  #8   Report Post  
Andy Dingley
 
Posts: n/a
Default

On Fri, 19 Nov 2004 12:18:47 -0600, Johnboy wrote:

I've read on the net PVC vs.
metal. It's like cars, everyone has thier own opinion. From what I've
read, I'm leaning towards metal


Metal's better, but the "exploding dust" reason is bogus.

Go with what you can afford and fit. Custom metalwork from a HVAC
shop is cheaper than you think.

--
Smert' spamionam
  #9   Report Post  
Andy Dingley
 
Posts: n/a
Default

On Sat, 20 Nov 2004 09:07:22 +0800, Old Nick
wrote:

muffs are a PITA.


In this weather they keep your ears warm.

  #10   Report Post  
Old Nick
 
Posts: n/a
Default

On Sat, 20 Nov 2004 02:45:35 GMT, mac davis
vaguely proposed a theory
.......and in reply I say!:

remove ns from my header address to reply via email

Again bigger pipe makes a huge difference.

interesting, nick.. and it makes sense..


Thank god for that! Doesn't happen often....G


I guess the elbow thing is sort of a "damned if you do, damned if you
don't" kind of thing, especially when applied to a cyclone..
I wouldn't want to use my DC without it, but among other issues,
you're adding at least 2 elbows to make it work..



I think it's why MinM was saying don't go across the ceiling. You add
one more right angle to each unit, and probably turbulence at each T
even when the air is going elsewhere. In fact I checked, and a Tee,
flow _through_ (not around)_ the Tee, is about as bad as an elbow,
going round the elbow. Going round from the cross to the leg of a Tee
is a killer. Tees are a real no-no according to this set of calcs.

Sweeping turns help quite a bit. The prebuilt elbow is the killer.

I don't know about cyclones, except that they free up the DC and the
bags so much that _sustained_ performance will be _hugely_ increased.

Inside the cyclone of course, the rules change. The air slows right
down, as you are effectively running a 2' diameter pipe! G
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Replacing flex duct with rigid sheet metal Jeffrey J. Kosowsky Home Repair 11 November 4th 04 04:48 AM
Dust collection at the table saw blade guard Dick Snyder Woodworking 19 September 27th 04 10:44 PM
Bosch 4000 TS & dust collection Dick Snyder Woodworking 0 September 24th 04 07:53 PM
Earth Bondng Adrian Simpson UK diy 8 March 21st 04 11:58 PM