Woodworking (rec.woodworking) Discussion forum covering all aspects of working with wood. All levels of expertise are encouraged to particiapte.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 27
Default Tenon Strength / Rail strength- Max?

Good evening-

I'm drawing up plans for a wine rack that will involve either 4 or 6
'posts' and a series of wood slats to hold the bottles. Each slat
(front and back) holds 10 bottles for a weight around 20 lbs, so not
very much. Each post will be approximately 6 foot tall which
translates into a 150 bottles, or about 200 lbs carrying (50lbs per
post).

The 'double wide' version would hold 50 lbs per post on the outer
posts, but the center two posts would be double-tenon and therefore
hold 100 lbs.

My concern is, not having built anything like this (I'll be making a
mockup with some with MDF when I get a free moment)- what do I need to
worry about? If I'm cutting into 2" post square stock and putting a 1"
high by 1/2" tenon into the post every 6 inches am I severely
compromising the carrying capacity of the wood? Or is it going to be
"OK" because the tenon (ideally) will fit perfectly and continue to
transmit the load to the floor.

The second question i"ll have later is how to cut multiple in register
partial chord circles over 44" of material, but that's another day's
issue...

Thanks in advance-

Jason

  #2   Report Post  
Posted to rec.woodworking
C&S C&S is offline
external usenet poster
 
Posts: 28
Default Tenon Strength / Rail strength- Max?

My concern is, not having built anything like this (I'll be making a
mockup with some with MDF when I get a free moment)- what do I need to
worry about? If I'm cutting into 2" post square stock and putting a 1"
high by 1/2" tenon into the post every 6 inches am I severely
compromising the carrying capacity of the wood?


No. The compressive strength of wood along the grain is very high. The
likely mode of failure would the the assembly bowing out. The wood on the
outside of the bow would be in tension and the wood on the inside would be
in compression. The wood in the middle is not under stress.

have you ever drilled holes in floor joists to run plumbing or wiring? When
you drill ahole in the middle it ahas nearly no effect on the strength of
the joist. If you notch the top or the bottom, you have significantly
compromised the joist. The mortises are in the middle so they have a minimal
impact.


Or is it going to be
"OK" because the tenon (ideally) will fit perfectly and continue to
transmit the load to the floor.


The other 1.5" of material is plenty to carry the load.


  #3   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 29
Default Tenon Strength / Rail strength- Max?


wrote:
Good evening-

I'm drawing up plans for a wine rack that will involve either 4 or 6
'posts' and a series of wood slats to hold the bottles. Each slat
(front and back) holds 10 bottles for a weight around 20 lbs, so not
very much. Each post will be approximately 6 foot tall which
translates into a 150 bottles, or about 200 lbs carrying (50lbs per
post).

The 'double wide' version would hold 50 lbs per post on the outer
posts, but the center two posts would be double-tenon and therefore
hold 100 lbs.

My concern is, not having built anything like this (I'll be making a
mockup with some with MDF when I get a free moment)- what do I need to
worry about? If I'm cutting into 2" post square stock and putting a 1"
high by 1/2" tenon into the post every 6 inches am I severely
compromising the carrying capacity of the wood? Or is it going to be
"OK" because the tenon (ideally) will fit perfectly and continue to
transmit the load to the floor.

The second question i"ll have later is how to cut multiple in register
partial chord circles over 44" of material, but that's another day's
issue...

Thanks in advance-

Jason


Without seeing exact plans for this, I would say the following
regarding your main concern: I'd personally be less concerned about
the vertical load on the post (assuming your tenons are snug and you
are using a fairly strong wood like oak, ash, or the like), than the
horizontal regidity your design may need to consider. With 200 lbs
going up 6 feet, you will want to make sure the center of gravity is'nt
too high, and that that it offers rigidity (maybe tie the posts
together diagonally every 2 feet vertically)

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Loose Tenon vs Mortise & Tenon AND/OR Who Do You Believe? charlie b Woodworking 2 April 17th 06 04:33 PM
Filling in gap around punched rail [email protected] Metalworking 7 January 18th 06 02:03 PM
M & T Joints. Near orgasmic experience Edwin Pawlowski Woodworking 8 December 30th 03 03:11 PM
Removing a hydronic towel heater rail help? Bob Mannix UK diy 1 July 10th 03 03:01 PM
Knife Steel FAQ updated Gunner Metalworking 9 June 26th 03 11:11 PM


All times are GMT +1. The time now is 09:30 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"