Default High level cistern flush too powerful

I have a problem with a new reproduction Victorian style high level cistern
installed above a bog, the bog and cistern are called a 'Savoy' if that
helps.
Problem is when I flush the cistern the head of water is so great that a few
splashes get outside on to the floor. The problem is minimised if the seat
is down, but knowing the inbuilt ability of the male species to leave the
seat up always - this is likely to be a problem.
The cistern is a 6 litre max flush, I have tried reducing the amount of
water in the tank to 4 litre via the Torbeck inlet valve but this doesn't
help much. I also can`t see an adjustment setting on the flush valve to slow
down the rate of water outlet to the bog once the chain is pulled.
The only solution I can think of is to reduce the height of the cistern, but
this would involve a lot of work & the cistern is meant to be at this height
anyway.
Has anyone had this problem before & if so how did they solve it ?

TIA
Steve


  #2   Report Post  
Lee
 
Posts: n/a
Default High level cistern flush too powerful

steve wrote:

I have a problem with a new reproduction Victorian style high level cistern
installed above a bog, the bog and cistern are called a 'Savoy' if that
helps.
Problem is when I flush the cistern the head of water is so great that a few
splashes get outside on to the floor. The problem is minimised if the seat
is down, but knowing the inbuilt ability of the male species to leave the
seat up always - this is likely to be a problem.
The cistern is a 6 litre max flush, I have tried reducing the amount of
water in the tank to 4 litre via the Torbeck inlet valve but this doesn't
help much. I also can`t see an adjustment setting on the flush valve to slow
down the rate of water outlet to the bog once the chain is pulled.
The only solution I can think of is to reduce the height of the cistern, but
this would involve a lot of work & the cistern is meant to be at this height
anyway.
Has anyone had this problem before & if so how did they solve it ?



If the problem is flow rate rather than the amount of head, as such,
maybe you could cobble together some sort of flow restricter in the
flush pipe? Maybe a rubber disc with holes or a piece of mesh?

Lee

--
To reply use lee.blaver and ntlworld.com
  #3   Report Post  
James Hart
 
Posts: n/a
Default High level cistern flush too powerful

steve wrote:
I have a problem with a new reproduction Victorian style high level
cistern installed above a bog, the bog and cistern are called a
'Savoy' if that helps.
Problem is when I flush the cistern the head of water is so great
that a few splashes get outside on to the floor. The problem is
minimised if the seat is down, but knowing the inbuilt ability of the
male species to leave the seat up always - this is likely to be a
problem.
The cistern is a 6 litre max flush, I have tried reducing the amount
of water in the tank to 4 litre via the Torbeck inlet valve but this
doesn't help much. I also can`t see an adjustment setting on the
flush valve to slow down the rate of water outlet to the bog once the
chain is pulled.
The only solution I can think of is to reduce the height of the
cistern, but this would involve a lot of work & the cistern is meant
to be at this height anyway.
Has anyone had this problem before & if so how did they solve it ?


Can you add an obstruction into the pipe between the 2 to restrict the
flowrate?

--
James...
www.jameshart.co.uk


  #4   Report Post  
Andy Hall
 
Posts: n/a
Default High level cistern flush too powerful

On Sat, 28 Feb 2004 16:14:04 -0000, "steve" wrote:

I have a problem with a new reproduction Victorian style high level cistern
installed above a bog, the bog and cistern are called a 'Savoy' if that
helps.
Problem is when I flush the cistern the head of water is so great that a few
splashes get outside on to the floor. The problem is minimised if the seat
is down, but knowing the inbuilt ability of the male species to leave the
seat up always - this is likely to be a problem.
The cistern is a 6 litre max flush, I have tried reducing the amount of
water in the tank to 4 litre via the Torbeck inlet valve but this doesn't
help much. I also can`t see an adjustment setting on the flush valve to slow
down the rate of water outlet to the bog once the chain is pulled.
The only solution I can think of is to reduce the height of the cistern, but
this would involve a lot of work & the cistern is meant to be at this height
anyway.
Has anyone had this problem before & if so how did they solve it ?

TIA
Steve


The easiest solution is to reduce the flow rate through the flush
pipe.

Disconnect it either at the pan or the cistern end and insert a
suitable reducer. Something made from a waste pipe blanking plug
that will fit inside the pipe ought to do it.

Experiment a little first to get the flow rate right, then you can fit
it in place with silicone sealant.

You hould be able to maintain the standard flush volume, but reducing
the rate will stop splashing, but just make the flush last a bit
longer.



..andy

To email, substitute .nospam with .gl
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Water cistern PoP UK diy 6 October 3rd 03 11:56 PM


All times are GMT +1. The time now is 05:13 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"