I recently found that my 2yr old CB28 boiler and new
central heating system never had any inhibitor chemical
added to the sealed system,the water is a bit brown. I've been
advised to clean the system and add inhibitor.

Once the cleaner has done its best, I thought I would be able to undo the
drain plug on the kitchen radiator, and
while the water pours out turn on the filling loop at the Combi boiler, thus
power flushing the entire system with
nice clean water.

Does this sound Ok or am I deluded.

Pete.


  #2   Report Post  
Set Square
 
Posts: n/a
Default Using a Combi Filling Loop as a Power Flush

In an earlier contribution to this discussion,
Pete wrote:

I recently found that my 2yr old CB28 boiler and new
central heating system never had any inhibitor chemical
added to the sealed system,the water is a bit brown. I've been
advised to clean the system and add inhibitor.

Once the cleaner has done its best, I thought I would be able to undo
the drain plug on the kitchen radiator, and
while the water pours out turn on the filling loop at the Combi
boiler, thus power flushing the entire system with
nice clean water.

Does this sound Ok or am I deluded.

Pete.



You are deluded.

Your method will only result in flushing the shortest part from the fill
point to the kitchen radiator. You need to:
* turn off and drain all radiators
* remove each one in turn and take it outside and wash it out with a hose
* with the radiator out, and the filling loop connected, open each radiator
valve (with a bucket handy) and run until the water is clear

That way, you'll flush *all* the pipes *and* the radiators.
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is Black Hole!


  #3   Report Post  
Pete
 
Posts: n/a
Default Using a Combi Filling Loop as a Power Flush


You are deluded.

Your method will only result in flushing the shortest part from the fill
point to the kitchen radiator. You need to:
* turn off and drain all radiators
* remove each one in turn and take it outside and wash it out with a hose
* with the radiator out, and the filling loop connected, open each

radiator
valve (with a bucket handy) and run until the water is clear

That way, you'll flush *all* the pipes *and* the radiators.
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is Black Hole!

===============================


Thanks for putting me strait.

Ouch!! that sounds like a heavy duty job, maybe I could
just add inhibitor seeing as the system is only 2yrs old and
halt any further corrosion.

Or am I double deluded

Pete.


  #4   Report Post  
Tim Small
 
Posts: n/a
Default Using a Combi Filling Loop as a Power Flush

Pete wrote:
You are deluded.

Your method will only result in flushing the shortest part from the fill
point to the kitchen radiator. You need to:
* turn off and drain all radiators
* remove each one in turn and take it outside and wash it out with a hose
* with the radiator out, and the filling loop connected, open each



Hmm, I'm not sure this is necessary (although it is probably the most
thoughrough way of doing it).

I had a similar problem - slack plumber had never flushed the system. I
added a drain valve on the return to the boiler. On my boiler, when it
is turned off, no water can flow from the fill point to the drain (i.e.
through the boiler heat exchanger). By fitting a bit of garden hose to
the drain point, closing all rads off, then opening each in turn, I
believe I was able to flush just about the entire system, without
disconnecting any rads..

Tim.
  #5   Report Post  
Andy Hall
 
Posts: n/a
Default Using a Combi Filling Loop as a Power Flush

On Sat, 14 Feb 2004 16:17:55 -0000, "Pete" wrote:


You are deluded.

Your method will only result in flushing the shortest part from the fill
point to the kitchen radiator. You need to:
* turn off and drain all radiators
* remove each one in turn and take it outside and wash it out with a hose
* with the radiator out, and the filling loop connected, open each

radiator
valve (with a bucket handy) and run until the water is clear

That way, you'll flush *all* the pipes *and* the radiators.
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is Black Hole!

===============================


Thanks for putting me strait.


.... and narrow :-)


Ouch!! that sounds like a heavy duty job, maybe I could
just add inhibitor seeing as the system is only 2yrs old and
halt any further corrosion.

Or am I double deluded


It really depends on how bad it is. A system without inhibitor can
be quite full of sludge in a matter of months if the tap water is
aggressive.

The proposal from Mr Set Square gives the right angle on this and I
would take that trouble if the system is microbore or there is any
sign of radiators feeling cool at the centre bottom when the heating
is on. This is because sludge build up in radiators tends to be at
the centre bottom. If it finds its way into the pipework, the flow
will become a problem.

Since you're depressurising anyway, then you could do a sample of one
upstairs and one downstairs radiator and decide from there.
If it isn't bad, then John's method works well as long as you have the
service valves and can direct the flow.

You can also add a system flushing agent (Fernox and Sentinel make
them) and run the system hot for the recommended time - normally up to
a week. Then thoroughly drain and flush and add the inhibitor.
Chemical flushing agents won't clear a heavily sludged system but
will help if the problem is fairly minor.








Pete.


..andy

To email, substitute .nospam with .gl


  #6   Report Post  
John Stumbles
 
Posts: n/a
Default Using a Combi Filling Loop as a Power Flush

"Pete" wrote in message
...

You are deluded.

Your method will only result in flushing the shortest part from the fill
point to the kitchen radiator.

You need to:
* turn off and drain all radiators
* remove each one in turn and take it outside and wash it out with a

hose
* with the radiator out, and the filling loop connected, open each

radiator
valve (with a bucket handy) and run until the water is clear

That way, you'll flush *all* the pipes *and* the radiators.



Thanks for putting me strait.

Ouch!! that sounds like a heavy duty job, maybe I could
just add inhibitor seeing as the system is only 2yrs old and
halt any further corrosion.



You can get a more thorough flush without going to the lengths of
individually flushing each rad by judiciously turning off radiator valves
and service valves on your boiler to force the water to go through other
paths. You'll need to know how it's all plumbed together to figure out how
to get it to do what you want. And/or you can just run it up to full
temperature then switch off and open up the drain cock to empty it; refill
and repeat a few times.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
power flushing Andy Hall UK diy 4 September 9th 03 11:59 PM
New Combi boiler GB UK diy 7 September 7th 03 11:34 PM


All times are GMT +1. The time now is 05:11 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"