Lighting circuit - loop through in switch



 
 
LinkBack Thread Tools Display Modes
  #1  
Old November 11th 03, 09:52 AM
Dan Sloane
external usenet poster
 
Posts: n/a
Default Lighting circuit - loop through in switch

I've recently started changing normal switches to dimmer switches in
my 1 ear-old home and noticed a very strange wiring technique....

Each of the switches I've changed so far have had the 'loop-through'
wiring done inside the wall switch. Most rooms are fitted with LV
halogen downlighters, so there's no ceiling rose - but surely the
looping should have been done in junction boxes.

Annoyingly, this means there's very little space in the back box for
the extended depth of a dimmer.

Can anyone please give me guidance whether this conforms to 16th
Edition regs, or if I should get another qualified electrician to
inspect.


Regards, Dan
Ads
  #2  
Old November 11th 03, 10:45 AM
John Watson
external usenet poster
 
Posts: n/a
Default Lighting circuit - loop through in switch

Hi John,
Each of the switches I've changed so far have had the 'loop-through'
wiring done inside the wall switch.

This is sometimes done, especially in older properties where there may not
be a ceiling void.

Annoyingly, this means there's very little space in the back box for
the extended depth of a dimmer.

This can be a real pain - as I'm sure you've found out. You may find you
need to fit deeper back boxes. They usually need a deeper back-box than the
16mm ones often used for light switches.

Can anyone please give me guidance whether this conforms to 16th
Edition regs, or if I should get another qualified electrician to
inspect.

Yes it does conform. Debatable whether it is good practice. In your case I'd
say it is good practice, as any joints are more easily accessible to inspect
etc. than ones hidden away in the ceiling void.

Interestingly this months "Professional Electrician" mag, Nov 03 p61 has an
NICEIC article that covers (more-or-less) this point.
--
John
"Dan Sloane" wrote in message
om...
I've recently started changing normal switches to dimmer switches in
my 1 ear-old home and noticed a very strange wiring technique....

Each of the switches I've changed so far have had the 'loop-through'
wiring done inside the wall switch. Most rooms are fitted with LV
halogen downlighters, so there's no ceiling rose - but surely the
looping should have been done in junction boxes.

Annoyingly, this means there's very little space in the back box for
the extended depth of a dimmer.

Can anyone please give me guidance whether this conforms to 16th
Edition regs, or if I should get another qualified electrician to
inspect.


Regards, Dan



  #3  
Old November 11th 03, 11:22 AM
Christian McArdle
external usenet poster
 
Posts: n/a
Default Lighting circuit - loop through in switch

Can anyone please give me guidance whether this conforms to 16th
Edition regs,


I don't think of any reason why it wouldn't conform, provided that the
correct terminals are used. It seems sensible, given that with downlighters
there isn't an obvious ceiling rose location to do the wiring.

Christian.



 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Case of the unknown circuit David Hearn UK diy 4 November 10th 03 04:12 PM
Longish query - circuit breakers in consumer units David W.E. Roberts UK diy 9 November 9th 03 12:33 PM
using 30A cable to supply 5A lighting circuit: good idea? dave L UK diy 3 October 7th 03 10:08 PM
Lighting Direct: A good company to do business with. parish UK diy 0 September 6th 03 09:35 PM
Lighting circuit problems Turv UK diy 2 August 22nd 03 06:50 AM


All times are GMT +1. The time now is 06:07 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.SEO by vBSEO ©2010, Crawlability, Inc.
Copyright 2004-2014 DIYbanter.
The comments are property of their posters.