#1
Posted to uk.d-i-y
|
|||
|
|||
using braided hose behind studwork
Can anyone advise please? Is it acceptable to use braided hose behind
a stud wall? I'm fitting a concealed citern loo and the final plumbing connection currently uses a braided flexible hose with a tap connector on one end. A hose like this: http://www.screwfix.com/p/flexible-t...-x-900mm/96597 Once the studding wall is built there will be no access to this hose. Is this considered OK or should I be using copper for this connection? thanks, Robert |
#2
Posted to uk.d-i-y
|
|||
|
|||
using braided hose behind studwork
On Jun 20, 11:08*am, RobertL wrote:
Can anyone advise please? *Is it acceptable to use braided hose behind a stud wall? I'm fitting a concealed citern loo and the final plumbing connection currently uses a braided flexible hose with a tap connector on one end. A hose like this: http://www.screwfix.com/p/flexible-t...-3-4-x-900mm/9... Once the studding wall is built there will be no access to this hose. Is this considered OK or should I be using copper for this connection? thanks, Robert Surely you have a removal panel for the loo cistern? Can't you make the panel a bit bigger to get access to the flexi? Or extend the fixed pipework and have a shorter flexi to the cistern - that is accessible? |
#3
Posted to uk.d-i-y
|
|||
|
|||
using braided hose behind studwork
On Jun 20, 11:19*am, " wrote:
On Jun 20, 11:08*am, RobertL wrote: Can anyone advise please? *Is it acceptable to use braided hose behind a stud wall? I'm fitting a concealed citern loo and the final plumbing connection currently uses a braided flexible hose with a tap connector on one end. A hose like this: http://www.screwfix.com/p/flexible-t...-3-4-x-900mm/9... Once the studding wall is built there will be no access to this hose. Is this considered OK or should I be using copper for this connection? thanks, Robert Surely you have a removal panel for the loo cistern? Can't you make the panel a bit bigger to get access to the flexi? Or extend the fixed pipework and have a shorter flexi to the cistern - that is accessible?- the loo has a removable panel concealed behind the flush buttons. It's the Grohe system - all the loo bits lift out through this hole (about 8" by 4") but the pipe in question is not accessible this way. I feel it 'ought' to be copper. Robert |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Stainless braided hose suppliers | Metalworking | |||
Which screws for drywall studwork | UK diy | |||
Which screws for drywall studwork | UK diy | |||
Which screws for drywall studwork | UK diy | |||
Which screws for drywall studwork | UK diy |