I had a CERT (Carbon Emission Reduction Target scheme) assessment the
other day.

There are three lofts that need extra insulation. One is fully boarded.
One has a few boards lying around on top of the joists to make it easier
to walk around. One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.

The agent pointedly asked me if it was OK to roll out insulation over
the boards, and to blow insulation into the tight space. When I asked
why I wouldn't want that, he replied vaguely that some people wouldn't
be happy with it, but wouldn't explain why not.

Is there any reason why I shouldn't have roll insulation over the
boards, and blown insulation where roll insulation would be impossible
to put in place?

--
Mike Barnes
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,538
Default Loft insulation: things to avoid?

Mike Barnes wibbled:

I had a CERT (Carbon Emission Reduction Target scheme) assessment the
other day.

There are three lofts that need extra insulation. One is fully boarded.
One has a few boards lying around on top of the joists to make it easier
to walk around. One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.

The agent pointedly asked me if it was OK to roll out insulation over
the boards, and to blow insulation into the tight space. When I asked
why I wouldn't want that, he replied vaguely that some people wouldn't
be happy with it, but wouldn't explain why not.

Is there any reason why I shouldn't have roll insulation over the
boards, and blown insulation where roll insulation would be impossible
to put in place?


Partly it's your choice - I rather be less efficient than have a loft I
couldn't store stuff in because the boards were buried under fluffy.

But - big but - the important question to ask is: will your electrical
cables stand being buried under =200mm insulation?

Under the worst case, if the cable is buried in the middle of too much
insulation, 2.5mm2 cable derates to rather less than the 20A it is required
to be capable of carrying in order to form part of a British 32A ring final
circuit. Electric shower cables and other high power circuits may be at
risk too.

Personally, I think loft insulator contractors should be Part P
registered[1].

Cheers

Tim

[1] If we must have Part P...
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,668
Default Loft insulation: things to avoid?

On Fri, 30 Jan 2009 11:56:08 +0000, Mike Barnes wrote:
One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.


How do they normally handle that in order to blow insulation in? Cut a
hole in the ceiling, up through the soffits, down through the roof, or
through a hole in an adjacent wall?

We've got a small section of the house with no access panel, and judging
by the way it's lost snow before anything else, there can't be much in
the way of insulation in there...

cheers

Jules

  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 948
Default Loft insulation: things to avoid?

In uk.d-i-y, Tim S wrote:
Mike Barnes wibbled:

I had a CERT (Carbon Emission Reduction Target scheme) assessment the
other day.

There are three lofts that need extra insulation. One is fully boarded.
One has a few boards lying around on top of the joists to make it easier
to walk around. One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.

The agent pointedly asked me if it was OK to roll out insulation over
the boards, and to blow insulation into the tight space. When I asked
why I wouldn't want that, he replied vaguely that some people wouldn't
be happy with it, but wouldn't explain why not.

Is there any reason why I shouldn't have roll insulation over the
boards, and blown insulation where roll insulation would be impossible
to put in place?


Partly it's your choice - I rather be less efficient than have a loft I
couldn't store stuff in because the boards were buried under fluffy.


We've had a larger garage built (not DIY , so we don't need the space
in the loft any more.

But - big but - the important question to ask is: will your electrical
cables stand being buried under =200mm insulation?


That would be the case whether or not the loft was boarded. As it
happens, there's only lighting up there - no problem.

--
Mike Barnes
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 948
Default Loft insulation: things to avoid?

In uk.d-i-y, Jules wrote:
On Fri, 30 Jan 2009 11:56:08 +0000, Mike Barnes wrote:
One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.


How do they normally handle that in order to blow insulation in? Cut a
hole in the ceiling, up through the soffits, down through the roof, or
through a hole in an adjacent wall?


In this case there is small hatch in one corner and I can squeeze in and
crawl halfway along, at the high side next to the first floor wall. The
other half has a slightly higher ceiling and no adult could get in
there. As soon as you move away from the wall... well, you can't, it's
too low, and there are trusses in the way. To make matters worse the
space is obstructed by three... I don't know what to call them, there's
a Velux window in the roof and four little walls going down from it to
the ceiling (times three). All in all you can get pretty close to
everywhere but there's no room to manoeuvre.

I'm assuming they'll go up with a tube, crawl in as far as they can,
spray as far as they can, then gradually retreat spraying as they go.
Even if they stood up in the hatch opening they could do a pretty good
job, depending on the strength of the spray of course.

We've got a small section of the house with no access panel, and judging
by the way it's lost snow before anything else, there can't be much in
the way of insulation in there...


We've got one of those as well but it's in an area we don't heat.

--
Mike Barnes


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 24
Default Loft insulation: things to avoid?


"Mike Barnes" wrote in message
...
In uk.d-i-y, Jules wrote:
On Fri, 30 Jan 2009 11:56:08 +0000, Mike Barnes wrote:
One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.


How do they normally handle that in order to blow insulation in? Cut a
hole in the ceiling, up through the soffits, down through the roof, or
through a hole in an adjacent wall?


In this case there is small hatch in one corner and I can squeeze in and
crawl halfway along, at the high side next to the first floor wall. The
other half has a slightly higher ceiling and no adult could get in
there. As soon as you move away from the wall... well, you can't, it's
too low, and there are trusses in the way. To make matters worse the
space is obstructed by three... I don't know what to call them, there's
a Velux window in the roof and four little walls going down from it to
the ceiling (times three). All in all you can get pretty close to
everywhere but there's no room to manoeuvre.

I'm assuming they'll go up with a tube, crawl in as far as they can,
spray as far as they can, then gradually retreat spraying as they go.
Even if they stood up in the hatch opening they could do a pretty good
job, depending on the strength of the spray of course.

We've got a small section of the house with no access panel, and judging
by the way it's lost snow before anything else, there can't be much in
the way of insulation in there...


We've got one of those as well but it's in an area we don't heat.

--
Mike Barnes


'Blow what'? Lofts around here (houses built 40 years ago) were insulated
with that polystyrene stuff that looks like popcorn. Now known to chemically
disagree with electric cable sheathing. It attaches and slowly dissolves
the cable sheath finally blowing the fuse. Worth seeing too, one length of
lighting cable I lifted must have had 200-300 bits of the crap firmly
embedded in the cable.

Peter


Peter


  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default Loft insulation: things to avoid?

In article ,
"Peter" writes:
'Blow what'? Lofts around here (houses built 40 years ago) were insulated
with that polystyrene stuff that looks like popcorn. Now known to chemically
disagree with electric cable sheathing. It attaches and slowly dissolves
the cable sheath finally blowing the fuse. Worth seeing too, one length of
lighting cable I lifted must have had 200-300 bits of the crap firmly
embedded in the cable.


Expanded polystyrene leaches the plasticiser out of PVC, which will
make the cable less flexible. It won't blow any fuses, unless you
go up there and start vigourously bending cables back and forth - if
you are losing fuses, that's a different problem.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,306
Default Loft insulation: things to avoid?

On Jan 30, 11:56*am, Mike Barnes wrote:
I had a CERT (Carbon Emission Reduction Target scheme) assessment the
other day.

There are three lofts that need extra insulation. One is fully boarded.
One has a few boards lying around on top of the joists to make it easier
to walk around. One is almost (but not quite) impossible to access,
being under a shallow roof over a single-storey extension.

The agent pointedly asked me if it was OK to roll out insulation over
the boards, and to blow insulation into the tight space. When I asked
why I wouldn't want that, he replied vaguely that some people wouldn't
be happy with it, but wouldn't explain why not.

Is there any reason why I shouldn't have roll insulation over the
boards, and blown insulation where roll insulation would be impossible
to put in place?



We had a similar problem with our victorian house there was a 100mm
gap between slates and lath+plaster ceiling. Blowing in fibres leaves
no air gap surely, also, fibre is not as good an insulator as Kinspan/
Celotex and if the space is limited it might be better to use one of
those.

First we decided to 'post' 50mm kingspan slabs in there leaving a 50mm
gap above them. then we decided to pull down the ceiling and lower it
creating bigger space for Kingspan. Havign sone that and examined the
roof thus exposed we decided to have it reslated as well.

Robert



  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 287
Default Loft insulation: things to avoid?

....... then we decided to pull down the ceiling and lower it
creating bigger space for Kingspan. Havign sone that and examined the
roof thus exposed we decided to have it reslated as well.

Robert





I'm thinking of leaving a ceiling as it is
then sticking kingspan underneath it
(with the vapour barrier downwards)
then a layer of plasterboard under that..

much less messy than removing an exisitng ceiling
can't see why not?

[g]
  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,306
Default Loft insulation: things to avoid?

On Feb 3, 2:04*pm, "george (dicegeorge)" wrote:
...... * then we decided to pull down the ceiling and lower it

creating bigger space for Kingspan. *Havign sone that and examined the
roof thus exposed we decided to have it reslated as well.


Robert


I'm thinking of leaving a ceiling as it is
then sticking kingspan underneath it
(with the vapour barrier downwards)
then a layer of plasterboard under that..

much less messy than removing an exisitng ceiling
can't see why not?


Sounds OK to me, we had originally planned to do that. Part fo the
reasoning was to conserve the old ceiling for posterity. However...

our decision to pull it down for us was based on a mixture of
reasons. First, it would reduce the height of the ceiling a little
more if we left the old ceiling up (by 50mm) and it was low already.
Second, we needed the void to be debris-free so rentokil could spray
it for woodworm, third: part of it was going to be damaged anyway when
a chimney breast was removed. Finally: When I made an inspection hole
I found it was full of debris in the void ; it seems that when the
slates has been replaced in the 1960s the builders had simply dumpoed
the old slates and bits of cement onto the top of the ceiling! So
for us, we just thought, oh what the hell, let's just pull it down.
It took me about 2 hours to pull down (onto plastic sheets) and my
wife about 2 hours to bag it up and take to the dump.

What an amazing amount of dust!!!!


Robert

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Loft insulation Andrew Gabriel UK diy 11 January 7th 09 09:38 PM
Loft insulation. Warm loft, colder bedrooms? [email protected] UK diy 2 October 27th 07 07:52 PM
Insulation on loft roof - insulation blankets...? Simon Hawthorne UK diy 10 April 18th 05 09:55 PM
Things stored in my loft get very smelly - is there a way to stop it? Rob K UK diy 4 July 28th 04 10:02 PM
Loft Insulation Dean Richard Benson UK diy 192 February 6th 04 03:31 PM


All times are GMT +1. The time now is 08:05 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"