All,

Basically, the downstairs radiators aren't working.

Central heating system: newly installed (three months ago) boiler
(downstairs) and hot water cylinder (upstairs). System upgaded from
pumped HW/gravity CH to fully pumped system. Pump in airing cupboard
beside HW cylinder, one of those three way motorised valve thingies
also in airing cupboard (which works).

Last week, before we switched the central heating on, I removed a rad
in upstairs toilet to knock down wall (see other thread "Bathroom from
scratch"). While removing the rad, I mde on of the valves leak, so
had to drain the system and put an end stop on one of the pipes to the
rad.

This was the first time I had drained a system, and I refilled it by
untying the ball cock to header tank, then bleeding all the rads. As
it was an emergency, 10pm at night, I did this without consulting the
archives on here and bled bled the upstairs rads first, then
downstairs, susbsequently finding out that this is the wrong way
round. I haven't yet redained the system and refilled corectly.

On finding that downstairs rads weren't working, I did a few searches
on here and tried the following:

- bled pump and checked that the impeller isn't stuck. No air came
out of pump, and impeller spinning freely.

- switched off all radiators apart from one downstairs furthest away
from pump/HWC, switched on heating...the rad which was previously
stone cold warmed up within 1 minute...very hot to touch. Bingo I
thought. Switched the rad off and did the same to all downstairs
rads...switching of all rads apart from the one I'm working on...each
heated up nicely. I also bled each one as it was switched on and hot
water came out.

- when I switched on all the rads..again, only the upstairs ones warm
up. This morning, every downstais one was stone cold, whereas before
they were all slightly warm to touch, but not hot like the upstairs
rads. The one in the downstairs bathroom is still stone cold.

I'm not sure what the problem is...each rad will heat up very hot if
it's the only rad on...but switch them all on and the downstairs ones
don't warm up. I'm pretty sure the pump is OK as a solitary switched
on rad, no matter where in the house will heat up almost
instantaneously.

Is this an airlock? It's just that I'm reluctant to call out the
plumber/heating engineer that installed it as he's a really nice chap,
and I don't want to look like a mug. Also, the rad ai removed will be
going back on, after the weekend,and I don't want to have to call him
out when I drain the system again and refit the rad. If I can't get
it to I'll call him out after I've refitted the rad...but would like
to at least have a warm shower room before...and it's not really in
the spirit of uk.diy....

Another question...when bleeding the pump via the big brass screw on
the back while the pump is on, is it normal to only have a little
dribble coming out...I would have thought that it would spurt
out...but would be happy to be wrong...

Many thanks for your help chaps...

Mark
  #2   Report Post  
BigWallop
 
Posts: n/a
Default central heating probs


"mark" wrote in message
m...
All,

Basically, the downstairs radiators aren't working.

Central heating system: newly installed (three months ago) boiler
(downstairs) and hot water cylinder (upstairs). System upgaded from
pumped HW/gravity CH to fully pumped system. Pump in airing cupboard
beside HW cylinder, one of those three way motorised valve thingies
also in airing cupboard (which works).

Last week, before we switched the central heating on, I removed a rad
in upstairs toilet to knock down wall (see other thread "Bathroom from
scratch"). While removing the rad, I mde on of the valves leak, so
had to drain the system and put an end stop on one of the pipes to the
rad.

This was the first time I had drained a system, and I refilled it by
untying the ball cock to header tank, then bleeding all the rads. As
it was an emergency, 10pm at night, I did this without consulting the
archives on here and bled bled the upstairs rads first, then
downstairs, susbsequently finding out that this is the wrong way
round. I haven't yet redained the system and refilled corectly.

On finding that downstairs rads weren't working, I did a few searches
on here and tried the following:

- bled pump and checked that the impeller isn't stuck. No air came
out of pump, and impeller spinning freely.

- switched off all radiators apart from one downstairs furthest away
from pump/HWC, switched on heating...the rad which was previously
stone cold warmed up within 1 minute...very hot to touch. Bingo I
thought. Switched the rad off and did the same to all downstairs
rads...switching of all rads apart from the one I'm working on...each
heated up nicely. I also bled each one as it was switched on and hot
water came out.

- when I switched on all the rads..again, only the upstairs ones warm
up. This morning, every downstais one was stone cold, whereas before
they were all slightly warm to touch, but not hot like the upstairs
rads. The one in the downstairs bathroom is still stone cold.

I'm not sure what the problem is...each rad will heat up very hot if
it's the only rad on...but switch them all on and the downstairs ones
don't warm up. I'm pretty sure the pump is OK as a solitary switched
on rad, no matter where in the house will heat up almost
instantaneously.

Is this an airlock? It's just that I'm reluctant to call out the
plumber/heating engineer that installed it as he's a really nice chap,
and I don't want to look like a mug. Also, the rad ai removed will be
going back on, after the weekend,and I don't want to have to call him
out when I drain the system again and refit the rad. If I can't get
it to I'll call him out after I've refitted the rad...but would like
to at least have a warm shower room before...and it's not really in
the spirit of uk.diy....

Another question...when bleeding the pump via the big brass screw on
the back while the pump is on, is it normal to only have a little
dribble coming out...I would have thought that it would spurt
out...but would be happy to be wrong...

Many thanks for your help chaps...

Mark


Did the system work when it was first installed ? The boiler is downstairs
and the only pump is upstairs, along with the motorised valve ?

The only thing I can suggest you try, is to turn down all the valves on the
return side of all the radiators. You'll have to find out how many turns
the valves takes from fully open t completely closed, then set them at only
half the amount of turns to give you roughly half closed on all of them. If
you see what I mean.

But only do this on the return side of each radiator. And if it has only
been installed for three months, then call the company back in and get them
to sort it properly. If the system can't have a radiator removed / replaced
when decorating without causing problems, then it ain't worth having. If it
can't be drained and refilled for maintenance without it cocking up, then it
is not doing its job properly. That's unless you've kinked a pipe
somewhere, or forgetten to turn a valve back on that you've told us about.
:-))


---
www.basecuritysystems.no-ip.com

Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.522 / Virus Database: 320 - Release Date: 29/09/03


  #3   Report Post  
Rick Hughes
 
Posts: n/a
Default central heating probs


"mark" wrote in message
m...
All,

Basically, the downstairs radiators aren't working.

Central heating system: newly installed (three months ago) boiler
(downstairs) and hot water cylinder (upstairs). System upgaded from
pumped HW/gravity CH to fully pumped system.



Assume that install is correct ? and problem is only since you removed a
rad ?

If so, it could be as simple as an air-lock which can be a bugger to remove.


If pump is variable head - turn it up to maximum, then close off all rads at
the lockshield valves, bar one ... which should be the furthest away from
boiler.
Crank up boiler temp to maximum, and set room stat to max .... hopefully
this will blast the water into the rad past the air lock, keep bleeding the
rad as you observe.

The extra temp in boiler will also help kettle off any air that gets into
it, once you get one working add the others one by one.


If the rad still does not get hot - then work your hands along the flow
from boiler - you may be able to see where it's getting to ... maybe as far
as a non operating zone valve.


Some ideas for you anyway.


Once you get it working suggest you balance in properly - I wrote a sect on
balancing for the FAQ many years ago, assume it is still there.


Rick


  #4   Report Post  
mark
 
Posts: n/a
Default central heating probs

"Rick Hughes" wrote in message ...
"mark" wrote in message
m...
All,

Basically, the downstairs radiators aren't working.

Central heating system: newly installed (three months ago) boiler
(downstairs) and hot water cylinder (upstairs). System upgaded from
pumped HW/gravity CH to fully pumped system.



Assume that install is correct ? and problem is only since you removed a
rad ?

If so, it could be as simple as an air-lock which can be a bugger to remove.


If pump is variable head - turn it up to maximum, then close off all rads at
the lockshield valves, bar one ... which should be the furthest away from
boiler.
Crank up boiler temp to maximum, and set room stat to max .... hopefully
this will blast the water into the rad past the air lock, keep bleeding the
rad as you observe.

The extra temp in boiler will also help kettle off any air that gets into
it, once you get one working add the others one by one.


If the rad still does not get hot - then work your hands along the flow
from boiler - you may be able to see where it's getting to ... maybe as far
as a non operating zone valve.


Some ideas for you anyway.


Once you get it working suggest you balance in properly - I wrote a sect on
balancing for the FAQ many years ago, assume it is still there.


Rick


Thansk fro the advice chaps. Finally got round to fixing the heating,
and this is is what I did:

Re-installed the rad I removed in the new position.

Drained the system.

When empty, I turned off all rad at normal valve and lockshield.
Refilled system, and then filled each radiator in turn via normal
valve (with blled screw out.

When each rad was full, switched on heating to full, and waited for
system to warm up. Then carried out a balancing procedure to the best
of my knowledge as I don't know the sequence of the rads.

This seemed to do the trick. All rads nice and hot, including all
downstairs ones...

Thanks again...

Mark
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Oil-fired central heating control? Frances UK diy 1 October 2nd 03 10:57 AM
No central heating - HW only threewayvalve and tank therm John UK diy 7 September 29th 03 09:18 AM
Central heating bypass circuit Paul Roman UK diy 14 September 15th 03 09:43 AM
Pool water in central heating system Andy Hall UK diy 1 September 2nd 03 05:01 PM
Further to my last post entitled 'Flushing and treating central heating question' David W.E. Roberts UK diy 0 July 29th 03 07:15 PM


All times are GMT +1. The time now is 10:55 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"