Due to the fact we ran out of Oil yesterday (should have checked!!) and it
will be a couple of days to get a supply, one disadvantage to a Stanley, no
heating hot water or cooking! carry-out and microwave it is then..... ,

I decided to use this opportunity to fit an immersion heater to the hot
water tank, now remove the blanking plug that was fitted by a 20st gorilla
in the factory, well after a spanner, hammer and a few curses, the tank
appears to start distorting if I put pressure on it? I have come to the
conclusion it is not going to come out without a fight! (1)

Anyone have any ideas how to get it out, preferably without replacing the
tank as well? (2)

Des

(1) after the incident last year when I fitted a shower pump, and it turned
out the cold water galvanised tank was more like a colander when the mud was
disturbed thankyou insurance .

(2) Then the original hot water tank which had the immersian heater in it
sprung a leak

ahh the pleasures of maintaining an old cottrage


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 93
Default Fitting an immersion heater

On Aug 6, 2:03 pm, "Dieseldes" wrote:

Anyone have any ideas how to get it out, preferably without replacing the
tank as well? (2)


Have you emptied it? Having it full of water can help prevent it from
distorting while trying to undo the blanking plug. You could also try
heating the blanking plug to free it up.

Alan


  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 754
Default Fitting an immersion heater

On 6 Aug, 14:03, "Dieseldes" wrote:
Due to the fact we ran out of Oil yesterday (should have checked!!) and it
will be a couple of days to get a supply, one disadvantage to a Stanley, no
heating hot water or cooking! carry-out and microwave it is then..... ,

I decided to use this opportunity to fit an immersion heater to the hot
water tank, now remove the blanking plug that was fitted by a 20st gorilla
in the factory, well after a spanner, hammer and a few curses, the tank
appears to start distorting if I put pressure on it? I have come to the
conclusion it is not going to come out without a fight! (1)

Anyone have any ideas how to get it out, preferably without replacing the
tank as well? (2)

Des

(1) after the incident last year when I fitted a shower pump, and it turned
out the cold water galvanised tank was more like a colander when the mud was
disturbed thankyou insurance .

(2) Then the original hot water tank which had the immersian heater in it
sprung a leak

ahh the pleasures of maintaining an old cottrage


The threads are probably stuck with the old plumbers favourite "boss-
white". An immersion ring spanner with a short handle and a 1.5lb
hammer to apply impacts to the end of it while the cylinder is full
and under pressure is the way to do it. You may have already creased
the shell so its probably buggered now. You ought to have looked
through the old threads in here - its been covered many times before.

  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 774
Default Fitting an immersion heater

On Mon, 06 Aug 2007 11:35:44 -0700, cynic
mused:

On 6 Aug, 14:03, "Dieseldes" wrote:
Due to the fact we ran out of Oil yesterday (should have checked!!) and it
will be a couple of days to get a supply, one disadvantage to a Stanley, no
heating hot water or cooking! carry-out and microwave it is then..... ,

I decided to use this opportunity to fit an immersion heater to the hot
water tank, now remove the blanking plug that was fitted by a 20st gorilla
in the factory, well after a spanner, hammer and a few curses, the tank
appears to start distorting if I put pressure on it? I have come to the
conclusion it is not going to come out without a fight! (1)

Anyone have any ideas how to get it out, preferably without replacing the
tank as well? (2)

Des

(1) after the incident last year when I fitted a shower pump, and it turned
out the cold water galvanised tank was more like a colander when the mud was
disturbed thankyou insurance .

(2) Then the original hot water tank which had the immersian heater in it
sprung a leak

ahh the pleasures of maintaining an old cottrage


The threads are probably stuck with the old plumbers favourite "boss-
white". An immersion ring spanner with a short handle and a 1.5lb
hammer to apply impacts to the end of it while the cylinder is full
and under pressure is the way to do it. You may have already creased
the shell so its probably buggered now. You ought to have looked
through the old threads in here - its been covered many times before.


You won't get an immmersion spanner on an immersion blanking plug.
--
Regards,
Stuart.
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 774
Default Fitting an immersion heater

On Mon, 06 Aug 2007 07:45:01 -0700, AlanC
mused:

On Aug 6, 2:03 pm, "Dieseldes" wrote:

Anyone have any ideas how to get it out, preferably without replacing the
tank as well? (2)


Have you emptied it? Having it full of water can help prevent it from
distorting while trying to undo the blanking plug. You could also try
heating the blanking plug to free it up.

You want to heat the metal around the plug, if you just heat the plug
it will expand in the whole and be even more stuck.
--
Regards,
Stuart.


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 58
Default Fitting an immersion heater


"Lurch" wrote in message
...
On Mon, 06 Aug 2007 07:45:01 -0700, AlanC
mused:

On Aug 6, 2:03 pm, "Dieseldes" wrote:

Anyone have any ideas how to get it out, preferably without replacing
the
tank as well? (2)


Have you emptied it? Having it full of water can help prevent it from
distorting while trying to undo the blanking plug. You could also try
heating the blanking plug to free it up.


It's still nearly full, and it's got insulation sprayed? on it. I have tried
again but it does not want to shift it has thread tape wrapped round.

You want to heat the metal around the plug, if you just heat the plug
it will expand in the whole and be even more stuck.


Though that gave me an idea, I am sure I have a spray freezer can
somewhere, if I can find it that it may work, if not I think I will be back
to plan B...

Des


  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 58
Default Fitting an immersion heater


"Lurch" wrote in message
...
On Mon, 06 Aug 2007 11:35:44 -0700, cynic
mused:

On 6 Aug, 14:03, "Dieseldes" wrote:
Due to the fact we ran out of Oil yesterday (should have checked!!) and
it
will be a couple of days to get a supply, one disadvantage to a
Stanley, no
heating hot water or cooking! carry-out and microwave it is then..... ,

I decided to use this opportunity to fit an immersion heater to the hot
water tank, now remove the blanking plug that was fitted by a 20st
gorilla
in the factory, well after a spanner, hammer and a few curses, the tank
appears to start distorting if I put pressure on it? I have come to the
conclusion it is not going to come out without a fight! (1)

Anyone have any ideas how to get it out, preferably without replacing
the
tank as well? (2)

Des

(1) after the incident last year when I fitted a shower pump, and it
turned
out the cold water galvanised tank was more like a colander when the mud
was
disturbed thankyou insurance .

(2) Then the original hot water tank which had the immersian heater in
it
sprung a leak

ahh the pleasures of maintaining an old cottrage


The threads are probably stuck with the old plumbers favourite "boss-
white". An immersion ring spanner with a short handle and a 1.5lb
hammer to apply impacts to the end of it while the cylinder is full
and under pressure is the way to do it. You may have already creased
the shell so its probably buggered now. You ought to have looked
through the old threads in here - its been covered many times before.


You won't get an immmersion spanner on an immersion blanking plug.


found out that one!


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fitting a New Immersion Heater [email protected] UK diy 37 June 21st 12 01:40 PM
Immersion Heater Macc Glyn UK diy 15 June 14th 07 06:03 PM
Immersion Heater The Medway Handyman UK diy 26 January 24th 07 09:21 PM
immersion heater painterman1 UK diy 9 December 30th 06 07:22 PM
Immersion heater [email protected] UK diy 7 February 3rd 06 02:47 PM


All times are GMT +1. The time now is 10:01 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"