combi boiler keeps on turning on
Hi - not sure if there is anything wrong with my boiler or not. i have
a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie |
#2
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
"debbieg" wrote in message ups.com... Hi - not sure if there is anything wrong with my boiler or not. i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie What model and how often does it come on and off? I mean, they are meant to turn off when the CH is up to temperature, then they come back on when the temperature drops, so it would help if we knew exactly what its doing. Andy. |
#3
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
On 17 Dec 2006 04:59:23 -0800 someone who may be "debbieg"
wrote this:- i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off How does it "seem to turn off"? Do you mean that the burners turn off? When they turn off the pump will probably still be running. and then starts straight back up again After how long? - continuously. For how long? Depending on the times this could be caused by a variety of things. For example some combination boilers have a hot water reservoir that they keep warm by intermittent firing. We will have more chance of guessing what it is with more information. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#4
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
On Sun, 17 Dec 2006 04:59:23 -0800, debbieg wrote:
Hi - not sure if there is anything wrong with my boiler or not. i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie What model? A stock fault on the VCW 242s is that the main PCB (the hardest to change) goes down with a fault that causes the CH to run continously. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
#5
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
Hah, I had a Vaillant which I replaced with a Halstead. This is almost
exactly the opposite of the fault I have at the moment (random tripping and locking out). When I find out what is wrong I will post the answer; good luck! |
#6
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
"debbieg" wrote in message ups.com... Hi - not sure if there is anything wrong with my boiler or not. i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie If you have a wireless programmer/thermostat, check the batteries in it. We have an Alpha boiler with wireless programmer/thermostat and if we happen to miss the low battery indicator on it (which is easy to do) the boiler goes into a sort of a hard-coded "failsafe" (I know that's not the phrase I need but can't think of anything better at the moment) 2 minutes on, 9 minutes off, cycle - and continues like that until the batteries are replaced. JellyBelly |
#7
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
JellyBelly wrote:
"debbieg" wrote in message ups.com... Hi - not sure if there is anything wrong with my boiler or not. i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie If you have a wireless programmer/thermostat, check the batteries in it. We have an Alpha boiler with wireless programmer/thermostat and if we happen to miss the low battery indicator on it (which is easy to do) the boiler goes into a sort of a hard-coded "failsafe" (I know that's not the phrase I need but can't think of anything better at the moment) 2 minutes on, 9 minutes off, cycle - and continues like that until the batteries are replaced. JellyBelly I have a Vailant combi boiler, it does this at odd times through the day, even when CH is switched off and no hot water is being drawn. when it was installed the installer told me this would happen as it keeps a small reservoir of hot water. Not sure of the model, if it is important I can root through my boxes and find out. |
#8
Posted to uk.d-i-y
|
|||
|
|||
combi boiler keeps on turning on
On Mon, 18 Dec 2006 17:25:01 +0000, Broadback wrote:
JellyBelly wrote: "debbieg" wrote in message ups.com... Hi - not sure if there is anything wrong with my boiler or not. i have a vailant combi boiler and no matter what heat setting it is at it comes on for a while with the burners going, seems to turn off and then starts straight back up again - continuously. I thought that it would keep on till it had reached the temp and then just keep blasting as and when needed - not keep going on and off the whole time? Any help would be appreciated. Thanks Debbie If you have a wireless programmer/thermostat, check the batteries in it. We have an Alpha boiler with wireless programmer/thermostat and if we happen to miss the low battery indicator on it (which is easy to do) the boiler goes into a sort of a hard-coded "failsafe" (I know that's not the phrase I need but can't think of anything better at the moment) 2 minutes on, 9 minutes off, cycle - and continues like that until the batteries are replaced. JellyBelly I have a Vailant combi boiler, it does this at odd times through the day, even when CH is switched off and no hot water is being drawn. when it was installed the installer told me this would happen as it keeps a small reservoir of hot water. Not sure of the model, if it is important I can root through my boxes and find out. Yes some models have the ability to do this. In general, to keep the boiler in warm standby is about 30s every 30 minutes. The OP was having the boiler run more than that. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
combi boiler - pressure increases then boiler shuts down | UK diy | |||
Help - I have a back boiler and want a combi boiler fitted but have plastic pipes! | Home Repair | |||
how much does it cost change back boiler to combi boiler | UK diy | |||
WICKS combi 82, Halstead combi boiler | UK diy | |||
Complicated central Heating; Back-Boiler and Combi-Boiler | UK diy |