Old November 9th 06, 05:53 PM posted to uk.d-i-y
external usenet poster
 
Posts: 11
Default Tubular Heater for Airing Cupboard

Hi,

I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?

Does anyone know where I can find a tubular heater with built-in
thermostat? If I cant find one with built-in then I will get a plug-in
type of thremostat to go with it.

Many thanks
Marc.c

Ads
  #2  
Old November 9th 06, 06:19 PM posted to uk.d-i-y
external usenet poster
 
Posts: 467
Default Tubular Heater for Airing Cupboard

Cokey wrote:

I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?

Does anyone know where I can find a tubular heater with built-in
thermostat? If I cant find one with built-in then I will get a plug-in
type of thremostat to go with it.


Hi Marc,

You could try this type of thing:
http://www.tlc-direct.co.uk/Main_Ind...m_1/index.html

It's impossible to say how powerful a heater you need, it depends on
how well insulated the cupboard is (and how hot you want it). I'd go
for a more powerful one and let the thermostat look after the
temperature control.

Martin

  #3  
Old November 10th 06, 02:00 AM posted to uk.d-i-y
external usenet poster
 
Posts: 15,389
Default Tubular Heater for Airing Cupboard

Cokey wrote:

I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?


I would probably go for the 120W

Does anyone know where I can find a tubular heater with built-in
thermostat? If I cant find one with built-in then I will get a plug-in
type of thremostat to go with it.


You can use an ordinary room stat. Most will switch small loads like
that without any difficulty.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #4  
Old November 10th 06, 08:53 AM posted to uk.d-i-y
external usenet poster
 
Posts: 9,377
Default Tubular Heater for Airing Cupboard

Cokey wrote:

I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?


Have you looked at a small dehumidifier (like the 70 on in Sainsburys)?

You get heat out of them (175W input) and they dry the air.

The fan circulates the air too so they work much better than a tubular
heater.


  #5  
Old November 10th 06, 08:55 AM posted to uk.d-i-y
external usenet poster
 
Posts: 3,357
Default Tubular Heater for Airing Cupboard

On 9 Nov 2006 09:53:30 -0800 someone who may be "Cokey"
wrote this:-

Does anyone know where I can find a tubular heater with built-in
thermostat?


It would be better to fit a separate one, remote from the heater.

If you have a wet central heating system then a pipe coil may be a
more economical way of heating the cupboard.


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #6  
Old November 10th 06, 09:47 AM posted to uk.d-i-y
external usenet poster
 
Posts: 15,389
Default Tubular Heater for Airing Cupboard

dennis@home wrote:

Cokey wrote:


I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?



Have you looked at a small dehumidifier (like the 」70 on in Sainsburys)?

You get heat out of them (175W input) and they dry the air.

The fan circulates the air too so they work much better than a tubular
heater.


Nice idea... what do they do with the water collected?

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #7  
Old November 10th 06, 10:18 AM posted to uk.d-i-y
external usenet poster
 
Posts: 11
Default Tubular Heater for Airing Cupboard

Thanks for all the responses guys. Im ordering a 120w tubular heater
and plug-in thermostat.

The idea about a pipe coil to heat the cupboard is great but
unfortunately I don't think it would be adequate enough to keep the
cupboard constantly warm (in my house at least), due to the central
heating not actually being on enough, especially during the warmer
times of year.

Marc.c

  #8  
Old November 10th 06, 10:54 AM posted to uk.d-i-y
external usenet poster
 
Posts: 2,121
Default Tubular Heater for Airing Cupboard

The message k
from "dennis@home" contains these words:


Have you looked at a small dehumidifier (like the 70 on in Sainsburys)?


Aldi have some - can't remember how much but it about half that.

--
Skipweasel
Pay no attention to that man behind the curtain.
  #9  
Old November 10th 06, 12:08 PM posted to uk.d-i-y
external usenet poster
 
Posts: 200
Default Tubular Heater for Airing Cupboard


"John Rumm" wrote in message
...
dennis@home wrote:

Cokey wrote:


I need a tubular heater for a new airing cupboard. The cupboard is
approx 100cm (w) x 100cm (d) x 250cm (h). I see that standard tubular
heaters come in 60w, 120w, 180w etc. What will I need to keep the
airing cupboard nice and warm? Will 60w be enough?



Have you looked at a small dehumidifier (like the ?70 on in Sainsburys)?

You get heat out of them (175W input) and they dry the air.

The fan circulates the air too so they work much better than a tubular
heater.


Nice idea... what do they do with the water collected?

--

The one we have has a container that fills with an optional facility to
drain via pipework if a suitable drain is nearby. The container on ours is
quite small so if I we were using it in a fixed position I would probably
sort a drain out.

H

H


  #10  
Old November 10th 06, 01:57 PM posted to uk.d-i-y
external usenet poster
 
Posts: 7,702
Default Tubular Heater for Airing Cupboard


"Cokey" wrote in message
ups.com...
Thanks for all the responses guys. Im ordering a 120w tubular heater
and plug-in thermostat.

The idea about a pipe coil to heat the cupboard is great but
unfortunately I don't think it would be adequate enough to keep the
cupboard constantly warm (in my house at least), due to the central
heating not actually being on enough, especially during the warmer
times of year.


Could you fit a radiator with an electric element? You can then use the
electric when the heating is off but still heat the cupboard without
electricity when the heating is on.

Adam

 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Water heater relief valve -- POW! [email protected] Home Repair 17 December 27th 05 07:42 PM
Kerosene Heater and De-humidifer Combo? Name Metalworking 39 December 11th 05 11:07 PM
Water heater in series to use as storage tank ... good or bad? Fred Home Repair 12 January 29th 05 01:38 PM
Building a cupboard into a (new) plasterboard wall James UK diy 1 May 3rd 04 12:20 PM
Electric Water Heater Problem, Repair or Buy new, please help Robert Home Repair 10 January 10th 04 01:09 AM


All times are GMT +1. The time now is 05:14 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.SEO by vBSEO ©2010, Crawlability, Inc.
Copyright 2004-2014 DIYbanter.
The comments are property of their posters.