Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to uk.d-i-y
|
|||
|
|||
Vaillant Ecotec 837 or WB Greenstar 35CDI combi ??
Have narrowed my choice of combi wall hung boiler down to
the Vaillant EcoTec plus 837 or the WB Greenstar 35CDI. Any helpful comments to assist with making the final decision ? Thanks Robert House spec is: large 3 beds, 3 floor midterrace, solid rubble walled (ie poor insulation) house. with 1 bathroom and 1 ensuite shower but little simultaneous use. Present boiler Ideal Mexico RS65 okay for CH & HW. Robert |
#2
Posted to uk.d-i-y
|
|||
|
|||
Vaillant Ecotec 837 or WB Greenstar 35CDI combi ??
On Mon, 19 Jun 2006 18:54:35 +0100, robert wrote:
Have narrowed my choice of combi wall hung boiler down to the Vaillant EcoTec plus 837 or the WB Greenstar 35CDI. Any helpful comments to assist with making the final decision ? Thanks Robert House spec is: large 3 beds, 3 floor midterrace, solid rubble walled (ie poor insulation) house. with 1 bathroom and 1 ensuite shower but little simultaneous use. Present boiler Ideal Mexico RS65 okay for CH & HW. Robert Frankly this is a bit over the top and you could probably save a few quid by down grading to the the 28-30kW versions. Also the gas pipe for the 35kW boilers will most likely have to be 28mm, but you'll probably have to upgrade anyway. Both makes are in the upper-mid market. The Vaillant has a s/s heat exchanger. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
#3
Posted to uk.d-i-y
|
|||
|
|||
Vaillant Ecotec 837 or WB Greenstar 35CDI combi ??
On Mon, 19 Jun 2006 20:13:47 +0100, Ed Sirett
wrote: On Mon, 19 Jun 2006 18:54:35 +0100, robert wrote: Have narrowed my choice of combi wall hung boiler down to the Vaillant EcoTec plus 837 or the WB Greenstar 35CDI. Any helpful comments to assist with making the final decision ? Thanks Robert House spec is: large 3 beds, 3 floor midterrace, solid rubble walled (ie poor insulation) house. with 1 bathroom and 1 ensuite shower but little simultaneous use. Present boiler Ideal Mexico RS65 okay for CH & HW. Robert Frankly this is a bit over the top and you could probably save a few quid by down grading to the the 28-30kW versions. Also the gas pipe for the 35kW boilers will most likely have to be 28mm, but you'll probably have to upgrade anyway. Both makes are in the upper-mid market. The Vaillant has a s/s heat exchanger. Agree the CH output is more than I need, but I need a decent HW flowrate and removal of HW cylinder is necessary as part of overall plan. Gas pipe will have to be replaced anyway its 15mm and about 25metre run at present. Robert Robert |
#4
Posted to uk.d-i-y
|
|||
|
|||
Vaillant Ecotec 837 or WB Greenstar 35CDI combi ??
lid wrote:
Gas pipe will have to be replaced anyway its 15mm and about 25metre run at present. If memory serves, I calculated a max effective length for 22mm pipe feeding a 35kW boiler at only 12m. So as Ed said, "bigger"! (Personally I would not go for less than 35kW - I find even that is only _just_ good enough) -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Vaillant condensing combi leak | UK diy | |||
Advice any combi or Vaillant Combi 828plus in loft? | UK diy | |||
Vaillant Aquaplus storage combi boiler | UK diy | |||
vaillant Turbomax 824/828 combi boilers | UK diy | |||
Vaillant Combi Boiler | UK diy |