LPG Boiler vent and extractor fan siting query
We are in the process of buying a rural cottage which has a wall mounted LPG
CH boiler, and an LPG Aga. Two questions: 1) My wife would like have a ducted extractor from above the Aga, but the only place to take it through the wall is beside the boiler. What are the limitations on distance between the vent and the flue? Would I need to fit a "chimney" to the vent to increase the distance from the flue? 2) We'd prefer to hide the boiler behind a fake wall cupboard door (no actual cupboard, just a removable panel across the front. Is this OK? Agin what clearance would apply? Is there somewhere I can read up about this? Thanks for your help, Ken -- --------------------------------------------------------- Ken Adam "Technology is pictures, not words" |
#2
Posted to uk.d-i-y
|
|||
|
|||
LPG Boiler vent and extractor fan siting query
In article , Ken
Adam writes We are in the process of buying a rural cottage which has a wall mounted LPG CH boiler, and an LPG Aga. Two questions: 1) My wife would like have a ducted extractor from above the Aga, but the only place to take it through the wall is beside the boiler. What are the limitations on distance between the vent and the flue? Would I need to fit a "chimney" to the vent to increase the distance from the flue? 2) We'd prefer to hide the boiler behind a fake wall cupboard door (no actual cupboard, just a removable panel across the front. Is this OK? Agin what clearance would apply? Is there somewhere I can read up about this? The manufacturer's installation instructions are the definitive guide and probably the easiest to obtain, usually from the mfr website. There are some generic rules about flue siting that are present in all installer guides and from mine, the closest I can find to your no.1 is "Horizontally from a terminal on the same wall - 300mm" but note "Vertically from a terminal on the same wall - 1500mm". Whilst your outlet is not a 'terminal' I think that this rule would be a safe starting point. On point no.2 I think you would be safe but you must look at the mfrs restrictions in the installer guide, some say not to be enclosed _at_all_. HTH -- fred Plusnet - I hope you like vanilla |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|