I have a largish (1m x 1m) Velux window which has misted between the panes.
Velux have quoted about £250 to replace the sealed unit. Is it possible to
DIY? Does anybody know the best place to get the sealed unit from? Access
from the inside is not completely straightforward, but too bad - the window
is about 2.5m above a half landing. No access from outside.

regards,
Andrew


  #2   Report Post  
Rick
 
Posts: n/a
Default

On Wed, 17 Aug 2005 10:16:42 +0100, "Andrew" - wrote:

I have a largish (1m x 1m) Velux window which has misted between the panes.
Velux have quoted about £250 to replace the sealed unit. Is it possible to
DIY? Does anybody know the best place to get the sealed unit from? Access
from the inside is not completely straightforward, but too bad - the window
is about 2.5m above a half landing. No access from outside.

regards,
Andrew


Sealed units can be got from any double glazing or glass shop.

You need to know the total thickness of the unit.

Rick

  #3   Report Post  
Set Square
 
Posts: n/a
Default

In an earlier contribution to this discussion,
Andrew - wrote:

I have a largish (1m x 1m) Velux window which has misted between the
panes. Velux have quoted about £250 to replace the sealed unit. Is it
possible to DIY? Does anybody know the best place to get the sealed
unit from? Access from the inside is not completely straightforward,
but too bad - the window is about 2.5m above a half landing. No
access from outside.

regards,
Andrew


I would contact one or two local private double-glazing companies (*not* the
national chains!). You should find someone who will come out and measure up
and then make and fit a new sealed unit for a lot less than Velux are
quoting.

If you're anywhere near Warwick, I would recommend Warwick Glass - but
similar firms exist elsewhere.
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is invalid.


  #4   Report Post  
in2minds
 
Posts: n/a
Default

I have a largish (1m x 1m) Velux window which has misted between the
panes.
Velux have quoted about £250 to replace the sealed unit. Is it
possible to
DIY? Does anybody know the best place to get the sealed unit from?
Access
from the inside is not completely straightforward, but too bad - the
window
is about 2.5m above a half landing. No access from outside.


there's a company near me that makes DG units, they'll knock up a DG
pane, any size, same day if you give them enough warning and rough
dimensions.
I took the original glass to the factory and they did one for me while I
waited, took them 30 minutes


  #5   Report Post  
Weatherlawyer
 
Posts: n/a
Default


Andrew wrote:

Velux have quoted about =A3250 to replace the sealed unit. Is it possible=

to
DIY?


If you can get a trestle set up for two to work on, removing a Velux
sash is a doddle. They unclip and lift up and of their hinge. Take it
off and have a look what you can do with it. Then, first thing next
day, take it to wherever for a refurb.

You can take it off by yourself if you are competent. Also you can take
it off from on the roof if you have roof ladders.

How long have you had the Velux?



  #6   Report Post  
Andrew
 
Posts: n/a
Default


"Weatherlawyer" wrote in message
oups.com...

If you can get a trestle set up for two to work on, removing a Velux
sash is a doddle. They unclip and lift up and of their hinge. Take it
off and have a look what you can do with it. Then, first thing next
day, take it to wherever for a refurb.


Can you expand on how to unclip the hinge? What aspect should the
window be in to do this? Can it then be slide directly through the
aperture, or will it be necessary to tilt it slightly obliquely? I'm
guessing the window unit will be about 15-20kg - it's the size and
weight of the window which is making me approach the task with
caution.

You can take it off by yourself if you are competent. Also you can take
it off from on the roof if you have roof ladders.


As it will be the first time I've done anything with a roof window, I guess
competency is a difficult thing to gauge. Presumably if I end up standing
around with a large hole in my roof and a mess of glass and wood on the
ground 5 storeys below me I will realise I am not as competent as I
thought I was...

How long have you had the Velux?


I don't know - the window is about 10-15 years old from what I can make out.

regards,
Andrew


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
replacing broken pane on double-insulated glass window Slumlord Home Repair 5 May 16th 05 02:50 PM
Replacing upvc window rubber seals cb UK diy 4 October 23rd 04 12:32 AM
Common and/or Legal definition of "casement window"? Me Home Repair 7 September 5th 04 05:20 PM
Problem closing Velux window Zargle UK diy 0 September 3rd 04 10:44 AM
window plugs for soundproofing xyz Home Repair 12 May 31st 04 11:55 PM


All times are GMT +1. The time now is 08:57 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"