  #1   Report Post  
 
Posts: n/a
Default how to drain a hot water pipe

I need to install a 22mm tee to my new en-suite but I have no way of
draining the 22mm pipe completely. Anyone have any good ideas on how to
do this?

There are no compression joints to losen...

Thanks.

G

  #2   Report Post  
andrewpreece
 
Posts: n/a
Default


wrote in message
oups.com...
I need to install a 22mm tee to my new en-suite but I have no way of
draining the 22mm pipe completely. Anyone have any good ideas on how to
do this?

There are no compression joints to losen...

Thanks.

G


Two ways, first is you cut the pipe in half at its lowest point, drain it,
then install a compression coupler so next time you'll be able to drain
it without all this palaver.

Second way, a bit unreliable, is to open the pipe up back along somewhere,
then open the relevant tap, fit some kind of rubber pipe to it, then blow
like
hell into the end. Very hard. Possibly until you see stars*. This may shift
the
pooled water so you are able to desolder the present solder fitting which is
at the moment proving impossible to desolder because of the pooled water
( am I guessing your problem correctly? ).

* If you have a heart attack or burst a blood vessel, don't blame me! ;-)

Andy.


  #3   Report Post  
Set Square
 
Posts: n/a
Default

In an earlier contribution to this discussion,
wrote:

I need to install a 22mm tee to my new en-suite but I have no way of
draining the 22mm pipe completely. Anyone have any good ideas on how
to do this?

There are no compression joints to losen...

Thanks.

G


This is presumably a hot water feed from the airing cupboard to an existing
bathroom and/or kitchen, and you wish to tee into it?

Is there an isolating valve in the feed pipe from the cold header tank to
the bottom of the hot cylinder? If so, turn that off and then open all (up
and down) hot taps. That should pretty much drain the pipes, but may leave a
small amount at any low points.

I would suggest using a copper push-fit tee such as
http://tinyurl.com/dqmbg In order to fit *any* tee, you'll need a bit of end
float in the pipe once you've cut it. Decide where the tee is the go, and
clean up the existing pipe in this region with wire wool. Mark the short
length of pipe which needs to be cut out to accommodate the tee. In the
centre of this section, as low as possible, drill a small hole - about 1/8"
diameter and catch any water which comes out in a suitable container. [A
foil take-away food container is ideal. If there is more than one
containerful, put a finger over the hole while you empty it into a larger
bowl.]

When no more water comes out, cut out the section of pipe containing the
hole using a ratchet-type pipe cutter such as http://tinyurl.com/cntae -
which can be used in a confined space. *Do not* use a hacksaw. Then you can
fit the tee, and take a supply to your en-suite.
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is invalid.


  #4   Report Post  
nick smith
 
Posts: n/a
Default

Or...

Partly cut the pipe with a wet and dry vacuum underneath to catch the drips,
when stopped cut all the way through, then apply full vacuum to each cut end to
SUCK all the water through out of the pipe. Also removes airlocks by sucking
them through

Nick


  #5   Report Post  
Capitol
 
Posts: n/a
Default


Wet & Dry vacuum cleaner, to suck water out of the pipe.

Regards
Capitol


  #7   Report Post  
Dave
 
Posts: n/a
Default

John Stumbles wrote:

OTOH if the pipe you're teeing
into is neatly positioned in the middle of 3 run side by side then you're
stymied as you can't tighten the nuts on the compression fitting.


Strap wrench, chain wrench will do this on a compression fitting. All
you have to do before hand, is compress the olives on a dummy pipe
fitting and then fit them in situ, using a strap wrench to tighten them
up :-)

HTH

Dave
  #8   Report Post  
nick smith
 
Posts: n/a
Default

as I suggested previously...............

Nick

"Capitol" wrote in message
...

Wet & Dry vacuum cleaner, to suck water out of the pipe.

Regards
Capitol



  #9   Report Post  
Chris McBrien
 
Posts: n/a
Default

Providing you are able to cut the 22mm pipe without flooding the place. Now
use a length of that transparent polythene pipe, as used in Wine making. Now
poke this down the 22mm. pipe as far as you need to and suck on the end and
allow it to syphon out the residual water or perhaps blow it out.


x-- 100 Proof News - http://www.100ProofNews.com
x-- 3,500+ Binary NewsGroups, and over 100,000 other groups
x-- Access to over 1.6 Terabytes per Day - $8.95/Month
x-- UNLIMITED DOWNLOAD

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
grounding water pipe William Deans Home Repair 50 February 19th 05 05:09 AM
Copper pipe sizing. Is bigger better? Paul J Home Repair 19 February 29th 04 08:52 PM
need hot water FAST PV Home Repair 38 January 30th 04 02:15 AM
NO MORE hot water problems [email protected] Home Repair 9 January 29th 04 07:15 PM
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money HeatMan Home Repair 0 August 24th 03 01:26 PM


All times are GMT +1. The time now is 04:11 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"