On Sunday, March 3, 2013 at 9:12:58 AM UTC+7, Ned Simmons wrote:
On Sat, 02 Mar 2013 15:11:34 -0500, wrote:

On Sat, 02 Mar 2013 07:29:27 -0800, Pilgrim
wrote:



--

Thanks for your informative reply. What are the thread specs? Std NPT or
something else. The couplings I have seen for GRC seen to be non tapered.
Is GRC meant to be liquid tight to prevent moisture entering?
Thanks

CP

GRC uses a NPS thread, not NPT (National Pipe Straight) not (National
Pipe Tapered)


I think this misunderstanding has been repeated here several times.
The threads on the ends of rigid conduit are tapered pipe threads.
Female threads on conduit fittings are often straight threads.

Per Wheatland:
"Wheatlands Galvanized steel Rigid Metal Conduit
(RMC) is manufactured in accordance with the latest
specifications and standards of ANSIĀ® C80.1, UL-6,
and federal specification WW-C-581. The pitch of
RMC threads conforms to the American National
Standard for Pipe Threads, General Purpose (Inch),
ANSI/ASME B1.20.1. The taper of threads is 3/4 inch
per foot (1 in 16). "
Ned, Contractor has brought steel tubing manufactured according to ASTM A53 (grade A) and buried it in concrete as electrical rigid conduit. Rigid conduit comes according to ANSI C-80.1


Can this steel pipe installed be threaded or made compatible with "real" ERSC pipe?

My email is


Please help if you can.
From NFPA 70 - 2008:
"344.28 Reaming and Threading. All cut ends shall be
reamed or otherwise finished to remove rough edges.
Where conduit is threaded in the field, a standard cutting
die with a 1 in 16taper (3/4-in. taper per foot) shall be used.
FPN: See ANSI/ASME B.1.20.1-1983, Standard for Pipe
Threads, General Purpose (Inch)."

--
Ned Simmons


  #42   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 1
Default Rigid Conduit vs Regular Iron pipe

I've bent miles of rigid pipe
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rerouting an 1/2" rigid electrical conduit in the attic MiamiCuse Home Repair 9 February 9th 09 03:16 AM
Installing pipe boots on roof. was cutting cast iron pipe in attic Mikepier Home Repair 4 September 27th 07 02:37 AM
Using a pipe as a conduit. [email protected] UK diy 10 November 14th 05 02:40 PM
Req'd: Cast Iron Soil Pipe bracket and Cast Iron>Plastic fittings John Borman UK diy 1 January 9th 05 10:05 PM
Can rigid EMT (electrical pipe) be used for projects...?? Ronnie Metalworking 25 January 1st 05 03:42 AM


All times are GMT +1. The time now is 01:32 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"