Default gutter drip edge problems

The gutters on my home leak in several places between the fascia board
and the gutters. The gutters are continuous aluminum with spike and
ferrule hangers nailed directly into the fascia board. There is a
metal drip edge installed above the gutters. The slope of the roof is
gradual (about 25 degrees) and it has standard asphault shingles. The
shingles overhang the metal drip edge. The problem is especially
noticable at both ends on the front of the house. The front gutter
run is 65 feet long.

It looks like the previous owner may have sloped the gutter too much
at the ends, and the top of the gutter is more than 2" below the
bottom of the drip edge at both ends of the run. In the middle, the
drip edge overlaps the top of the gutter. Isn't the sloping supposed
to be in the fascia board, and not the gutter against the board? It
also looks like the metal drip edge was installed so that the dripping
line is in direct contact with the fascia board. When it rains, the
water runs down the drip edge, onto the board and drips to the ground,
bypassing the gutter.

I found a product from Gutters Direct, called a No Drip Strip
http://shop.store.yahoo.com/guttersd...ripstrip3.html that looks
like it should solve the problem. It looks to be a strip of aluminum
flashing, maybe 2" wide. Plain aluminum flashing might work just as
well. Perhaps if I inserted the drip strip behind the drip edge and
let it hang into the gutter (nailing it into the fascia board), it
would keep the water in the proper channel. I've also heard about a
similar product that's asphault, that has self-adhesive and can be
rolled out and inserted in a similar way. The asphault product has a
vapor barrier, supposedly to prevent mildew problems.

Does anyone have experience with this type of situation? Should I
just remove the drip edge pieces pull them forward maybe 0.5", and
renail them to the roof? Perhaps this would solve the problem if the
drip edge dripped off into space, rather than against the wood. If I
install aluminum flashing, will this cause a problem with mold? Has
anyone seen the asphault type of product? The house is in a heavily
wooded area.

Any advice much appreciated.
  #2   Report Post  
Randd01
 
Posts: n/a
Default gutter drip edge problems

I had the same problem and used the strip of aluminium no drop strip to resolve
it. It works great now.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
tig welding problems drew j. Metalworking 4 November 25th 03 09:48 PM
Replacing copper gutter under slate charlie karnes Home Repair 2 July 7th 03 08:11 PM


All times are GMT +1. The time now is 05:00 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"