  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default sealing A/C ducts & boots by registers

am looking to take off all registers inside house and use mastic to seal all the
boots. is it as simple a job as just covering hand with latex glove and smearing a
generous amount into the area where the boot meets the sheetmetal duct?

any info or corrections are appreciated. home depot sells the mastic so I know at
least where to get it


  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14,845
Default sealing A/C ducts & boots by registers

On 2 Jul, 09:24, "Mike" wrote:
am looking to take off all registers inside house and use mastic to seal all the
boots. is it as simple a job as just covering hand with latex glove and smearing a
generous amount into the area where the boot meets the sheetmetal duct?

any info or corrections are appreciated. home depot sells the mastic so I know at
least where to get it


What's a boot?

And why are we doing this?

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 128
Default sealing A/C ducts & boots by registers

On Mon, 2 Jul 2007 16:24:35 +0300, "Mike" wrote:

am looking to take off all registers inside house and use mastic to seal all the
boots. is it as simple a job as just covering hand with latex glove and smearing a
generous amount into the area where the boot meets the sheetmetal duct?

any info or corrections are appreciated. home depot sells the mastic so I know at
least where to get it


That may or may not help. Do you know that you have leaks there that
need sealing?

What's the R Value of your ducts? Lowes sells insulated ducts that
are likely double the R Value of yours. So replace them.




  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2
Default sealing A/C ducts & boots by registers

DerbyDad03 wrote:
What's a boot?


end of runs of the insulated sheetmetal, in the attic, terminate in a boot
which attaches to the registers

And why are we doing this?


for the purpose of sealing some small leaks where warm air from attic is
mixed into the cooled air flowing from the register. this should improve
performance a little bit and would also stop a couple registers from
dripping condensate (inside temp is 77F but air from register is coming in
at 59-61 and a couple leaky boots are condensing on the outer surface)

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2
Default sealing A/C ducts & boots by registers

ValveJob wrote:
That may or may not help. Do you know that you have leaks there that
need sealing?


yes, a few registers are sucking in warm air. was there anything in my
description what was wrong? I mean to the process of applying mastic?

What's the R Value of your ducts? Lowes sells insulated ducts that
are likely double the R Value of yours. So replace them.


the house is rather large so not quite a simple job to pull out the existing
and inject new sheetmetal into the attic. the ones I now have are rather
sturdy, made from galvanized sheetmetal and appear very well wrapped, no
moisture is detected and no temp variations from the few times I've crawled
the length of the "pipes"

for now, just wanted to seal the registers & boots




  #6   Report Post  
Posted to alt.home.repair
M Q M Q is offline
external usenet poster
 
Posts: 257
Default sealing A/C ducts & boots by registers

mike wrote:

DerbyDad03 wrote:

What's a boot?



end of runs of the insulated sheetmetal, in the attic, terminate in a
boot which attaches to the registers

And why are we doing this?



for the purpose of sealing some small leaks where warm air from attic is
mixed into the cooled air flowing from the register. this should improve
performance a little bit and would also stop a couple registers from
dripping condensate (inside temp is 77F but air from register is coming
in at 59-61 and a couple leaky boots are condensing on the outer surface)


In my experience, boots are often installed by cutting a hole
about 1" larger than the boot in the floor / ceiling, then stuffing the
boot in with minimal attachment. Consequently, there if often
a lot of air leaking between the boot and the ceiling / floor.
First, if the boot seem loose, do what you can to secure it.
Then caulk or seal the gap with whatever you can (latex caulk,
foam caulk, duct mastic, etc.).
If you think that the joint between the boot and the duct is also leaking
(I have not seen this to be as big of an issue), seal that too.
If you can get to the outside of the duct do it on the outside.
If you use mastic, I would get a small paint brush -- metal edges can be
quite sharp and would easily cut through a latex glove.
Insulate the outside of the boot if it isn't already.

  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 128
Default sealing A/C ducts & boots by registers

On Mon, 2 Jul 2007 19:01:33 +0300, "mike" wrote:

ValveJob wrote:
That may or may not help. Do you know that you have leaks there that
need sealing?


yes, a few registers are sucking in warm air. was there anything in my
description what was wrong? I mean to the process of applying mastic?

What's the R Value of your ducts? Lowes sells insulated ducts that
are likely double the R Value of yours. So replace them.


the house is rather large so not quite a simple job to pull out the existing
and inject new sheetmetal into the attic. the ones I now have are rather
sturdy, made from galvanized sheetmetal and appear very well wrapped, no
moisture is detected and no temp variations from the few times I've crawled
the length of the "pipes"

for now, just wanted to seal the registers & boots


Then I'd say your solution is absolutely correct. We know it
should have been liberally applied when the boots were first
installed, but your method should work to fix what wasn't installed
properly or deteriorated over time.



  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14,845
Default sealing A/C ducts & boots by registers

On 2 Jul, 11:58, "mike" wrote:
- DerbyDad03 wrote:

- - What's a boot?

- end of runs of the insulated sheetmetal, in the attic, terminate
in a boot which attaches to the registers

Insulated sheetmetal? Ducts in an attic? Boots and registers?

Man, I need a new house!

  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 147
Default sealing A/C ducts & boots by registers

Just make sure you clean around the area that you want to reseal so the tape and mastic will seal properly.

--
Moe Jones
HVAC Service Technician
Energy Equalizers Inc.
Houston, Texas
www.EnergyEqualizers.com
"Mike" wrote in message ...
am looking to take off all registers inside house and use mastic to seal all the
boots. is it as simple a job as just covering hand with latex glove and smearing a
generous amount into the area where the boot meets the sheetmetal duct?

any info or corrections are appreciated. home depot sells the mastic so I know at
least where to get it


  #10   Report Post  
Posted to alt.home.repair
Zed Zed is offline
external usenet poster
 
Posts: 2
Default sealing A/C ducts & boots by registers

1. It may be easier to use caulk if you are sealing small cracks.
2. Instead of applying the mastic to a gloved hand, try a cheap paint brush.
It's better than snagging your hand on a sheet metal meat hook.
3. Make sure you seal the return system.



"Mike" wrote in message
...
am looking to take off all registers inside house and use mastic to seal
all the boots. is it as simple a job as just covering hand with latex
glove and smearing a generous amount into the area where the boot meets
the sheetmetal duct?

any info or corrections are appreciated. home depot sells the mastic so I
know at least where to get it






  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 165
Default sealing A/C ducts & boots by registers

Use a cheap 2" brush that has fairly stiff bristles. If there is an a/c
supply house near you, see if they will sell you a gallon of duct
sealer. The stuff HD and Lowes carry is not as good as what is used in
the trade, and they get about as much or a small container(quart?) as a
gallon costs at the supply house. There are several brands, all about
the same, that wholesale for about $11-14/gal, though they may charge a
homeowner more, assuming they will sell it to you at all. They will also
most likely have the brushes too. BTW, you are probably thinking the
stuff is thicker than it really is. It is about the same consistancy as
drywall mud. Good luck Larry

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Air registers Grip Home Repair 1 January 27th 07 02:36 AM
Installing ceiling boots (basement hvac) Brian Home Repair 1 February 4th 06 01:22 PM
difficult boots Ams UK diy 7 November 27th 05 09:41 PM
Cheap safety boots at Aldi today Lobster UK diy 3 February 14th 05 09:24 PM
Sealing Ducts in damp crawl space George Sambataro Home Repair 6 October 28th 04 02:28 AM


All times are GMT +1. The time now is 05:14 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"