Default TV antenna grounding question

Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?

If more grounding is needed, how should it be done?




  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 521
Default TV antenna grounding question

see:
http://www.arrl.org/tis/info/lightning.html

Kurt Gavin wrote:
Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?

If more grounding is needed, how should it be done?


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default TV antenna grounding question


buffalobill wrote:
see:
http://www.arrl.org/tis/info/lightning.html

Kurt Gavin wrote:
Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?


If all it takes for an adequate lightning protection ground is a steel
pole a foot in the ground, why is everyone else using real ground rods?
I'm surprised a pole a foot in the ground can even support the
antenna.

If it were my install, it would have a proper ground on the mast, as
well as a lightning arrestor with ground where the cable enters the
building.




If more grounding is needed, how should it be done?


  #4   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default TV antenna grounding question

On Tue, 31 Oct 2006 15:55:06 GMT, "Kurt Gavin"
wrote:

Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?


Lightening strikes are too big to bleed. If lightening did hit
something like that,I think it would melt into a puddle.

Your first qustion was on target, bleeding charges to the ground, or
call it, dispersing them to the ground. At any rate, it's too keep
something from attracting the lightening by being the opposite charge
(positive, I guess).

Otherwise the lightening rods on barns and houses would't work. They
are to thin and the wires going to them are too thin to carry even a
small lightening bolt.

That's what they say, at least. I don't really understand all of this.

Your pole is fine. But the problem would be the antenna elements,
which are insulated from the pole, right? Whether you are using cabel
or flat lead, there are lightening arrestors made for it, and I think
you need at least one, and maybe one at each end of the cable, the
mast and just before the house.

If more grounding is needed, how should it be done?




  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 674
Default TV antenna grounding question


"Kurt Gavin" wrote in message
.net...
Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?

If more grounding is needed, how should it be done?


No matter what you do, in the unlikely event that lightning does strike the
pole/antenna it will likely be destroyed or severely damaged, along with the
cable and TV set. Good grounding and lightning arrestors do give some
protection from nearby strikes, which otherwise can be very damaging.

Don Young




  #6   Report Post  
Junior Member
 
Posts: 1
Default

Quote:
Originally Posted by Kurt Gavin
Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?

If more grounding is needed, how should it be done?
Proper TV antenna grounding procedures can be found on this page http://www.dennysantennaservice.com/1171010.html
  #7   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default TV antenna grounding question

On Tue, 31 Oct 2006 20:10:14 -0500, mm
wrote:

On Tue, 31 Oct 2006 15:55:06 GMT, "Kurt Gavin"
wrote:

Does an outdoor TV antenna mounted on a regular 7 ft steel fence pole need
further grounding. (It works fine for local stations).

In other words, the steel pole is about a foot into the soil, and the
antenna is bolted to it. (There's also a guy wire for stability).

This should bleed builtup charges to the ground, right?

This should bleed a lightening strike to the ground, right?


Lightening strikes are too big to bleed. If lightening did hit
something like that,I think it would melt into a puddle.

Your first qustion was on target, bleeding charges to the ground, or
call it, dispersing them to the ground. At any rate, it's too keep
something from attracting the lightening by being the opposite charge


Oops. Lightning! I've wondered about the spelling for a year or two.
Maybe I'll remember now.

(positive, I guess).

Otherwise the lightening rods on barns and houses would't work. They
are to thin and the wires going to them are too thin to carry even a
small lightening bolt.

That's what they say, at least. I don't really understand all of this.

Your pole is fine. But the problem would be the antenna elements,
which are insulated from the pole, right? Whether you are using cabel
or flat lead, there are lightening arrestors made for it, and I think
you need at least one, and maybe one at each end of the cable, the
mast and just before the house.

If more grounding is needed, how should it be done?




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Ground Rod Diameter vs grounding performance question BobK207 Home Repair 12 September 20th 06 04:15 AM
electrical grounding question J.C. Home Repair 0 December 5th 05 02:10 PM
electrical grounding question Keith Boeheim Home Repair 12 December 5th 05 05:01 AM
Another subpanel grounding question Korey Atterberry Home Repair 9 July 7th 04 01:30 PM


All times are GMT +1. The time now is 02:26 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"