Insulation questions
Live in cold midwest - am getting ready to drywall portions of my house
that have been re-modeled. Wanted some recomendations on insulation r-values. Contractor did the construction, but I am doing insulation to save a few bucks.. Going with fiberglass... for ease of instalation.. etc. Outside walls - currently has r-11 but most has come down.. so will be replacing the stuff that has been exposed by removal of drywall. What R value should I go with. Ceiling between 1st and 2nd floor - Had insulation between joists, I have to assume it was for noise. Most has come down during contruction, will be replacing it. What R value? Bedroom walls - build a second floor laundry, want to sound insulate as much as possible.. what r-value should I use in walls (regular 2x4 stud walls) Have to get this done in the next 48 hours, so any specialized products are not an option, has to be off-the shelf from Lowes or HD (or simular) |
#2
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
"Jack" wrote in message Going with fiberglass... for ease of instalation.. etc. Outside walls - currently has r-11 but most has come down.. so will be replacing the stuff that has been exposed by removal of drywall. What R value should I go with. Go with R-asmuchasyoucan The deciding factor will be the wall cavity. You can only fit so much material in the space of a 2 x 4 or 2 x 6. Only other wayis to use a different mateial wiht a higher R value per inch. Ceiling between 1st and 2nd floor - Had insulation between joists, I have to assume it was for noise. Most has come down during contruction, will be replacing it. What R value? If both spaces are heated equally, it will make no real difference. Bedroom walls - build a second floor laundry, want to sound insulate as much as possible.. what r-value should I use in walls (regular 2x4 stud walls) R value has nothing to do with sound insulation. Thee are some materials that are supposed to help though. Check out hte Owens-Corning web page for what they offer. |
#3
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
As important as R is air seal -- Tyvek or equivalent.
Jack wrote: Live in cold midwest - am getting ready to drywall portions of my house that have been re-modeled. Wanted some recomendations on insulation r-values. Contractor did the construction, but I am doing insulation to save a few bucks.. Going with fiberglass... for ease of instalation.. etc. Outside walls - currently has r-11 but most has come down.. so will be replacing the stuff that has been exposed by removal of drywall. What R value should I go with. Ceiling between 1st and 2nd floor - Had insulation between joists, I have to assume it was for noise. Most has come down during contruction, will be replacing it. What R value? Bedroom walls - build a second floor laundry, want to sound insulate as much as possible.. what r-value should I use in walls (regular 2x4 stud walls) Have to get this done in the next 48 hours, so any specialized products are not an option, has to be off-the shelf from Lowes or HD (or simular) |
#4
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
Jack wrote:
Live in cold midwest - am getting ready to drywall portions of my house that have been re-modeled. Wanted some recomendations on insulation r-values. Contractor did the construction, but I am doing insulation to save a few bucks.. Going with fiberglass... for ease of instalation.. etc. Outside walls - currently has r-11 but most has come down.. so will be replacing the stuff that has been exposed by removal of drywall. What R value should I go with. The most that will fit in the cavity without compressing it. Ceiling between 1st and 2nd floor - Had insulation between joists, I have to assume it was for noise. Most has come down during contruction, will be replacing it. What R value? Since there should be little or no temperature difference R value is meaningless. Bedroom walls - build a second floor laundry, want to sound insulate as much as possible.. what r-value should I use in walls (regular 2x4 stud walls) I suggest adding an additional layer of drywall as that will do far more good than stuffing standard insulation in there. The do make some sound control insulation that will help some. Even more important would be any air to air exchanges. For example you don't want to use a shared air return as the sound will just travel through it from room to room. Laundries have a special issue with vibration. You want to isolate the machinery from the structure with flexible materials. You should be able to find a lot of ideas and maybe some products at: http://www.soundproofing.org/ You also want to prevent any direct solid connections. Stagger wall studs or use special isolation devices to keep the sound from traveling through the wall (remember the two cans on a string (well wire actuarially worked) you want to break the wire). Filling in wall cavities with sound absorbing materials (accustical fiberglass bats) will do a little. Have to get this done in the next 48 hours, so any specialized products are not an option, has to be off-the shelf from Lowes or HD (or simular) The isolation stuff for the equipment can be done later. -- Joseph Meehan Dia duit |
#5
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
First you need to air seal any potential avenues for air filtration
http://www.energystar.gov/index.cfm?...vement_sealing I used the Dow spray foam that comes in a can -- get closed cell type. Then add as much insulation that you can without compressing the fiberglass. Good luck. "Jack" wrote in message ups.com... Live in cold midwest - am getting ready to drywall portions of my house that have been re-modeled. Wanted some recomendations on insulation r-values. Contractor did the construction, but I am doing insulation to save a few bucks.. Going with fiberglass... for ease of instalation.. etc. Outside walls - currently has r-11 but most has come down.. so will be replacing the stuff that has been exposed by removal of drywall. What R value should I go with. Ceiling between 1st and 2nd floor - Had insulation between joists, I have to assume it was for noise. Most has come down during contruction, will be replacing it. What R value? Bedroom walls - build a second floor laundry, want to sound insulate as much as possible.. what r-value should I use in walls (regular 2x4 stud walls) Have to get this done in the next 48 hours, so any specialized products are not an option, has to be off-the shelf from Lowes or HD (or simular) |
#6
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
seal all around outlets etc, use unfaced insulation and cover all inside walls with heavy mill plastic like 10 mill. the big rush 48 hours isnt good it will lead to cuttiong corners and endless energy loss..... I would price closed cell foam in place, its sound deadening and a excellent insulator, but requires a pro install. if you ever heat just some rooms like we do insulate between floors |
#7
Posted to alt.home.repair
|
|||
|
|||
Insulation questions
Fiberglass batt is all apx the same 3.5R per inch, if you want to save
use R 7.2" foamboard, you wont save on heating using fiberglass over what you had |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Additional attic insulation??? | Home Repair | |||
doubling attic insulation - does it help? | Home Repair | |||
another insulation question | UK diy | |||
Best Insulation Scheme for a Finished Attic | Home Repair | |||
Fixing loft boarding *through* insulation and derating cable. | UK diy |