Default Running wires...

I just bought some small reading lights that I'd like to install over
my bed and I was hoping to run the wire (single wire for power) behind
the wall down to a power outlet at the baseboard. My concern is that
the power wire is very thin and I'm wondering if this is a potential
fire hazard; any ideas on that? My overall plan is to drill a small
hole just behind the light and let the wire dangle behind the wall, it
would come out near the baseboard where it will be connected to a surge
protector connected to a standard power outlet. Any issues with that
plan?
Thanks,
Dan

  #2   Report Post  
Posted to alt.home.repair
RBM
 
Posts: n/a
Default Running wires...

In the U.S. the NEC prohibits running lamp cord in walls, however metal and
plastic sleeves are made that attach to the wall surface for you to run the
zip cord inside of



wrote in message
oups.com...
I just bought some small reading lights that I'd like to install over
my bed and I was hoping to run the wire (single wire for power) behind
the wall down to a power outlet at the baseboard. My concern is that
the power wire is very thin and I'm wondering if this is a potential
fire hazard; any ideas on that? My overall plan is to drill a small
hole just behind the light and let the wire dangle behind the wall, it
would come out near the baseboard where it will be connected to a surge
protector connected to a standard power outlet. Any issues with that
plan?
Thanks,
Dan



  #3   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Running wires...

Any good examples of this? I'm looking for the cleanest display I can
get... are there many options of these sleeves?

  #4   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Running wires...

Thanks for the advise, I think you guys have convinced me to stay away
from this solution and go with the sleeve! Although, one question that
I have from the previous reply: you said to never run a plastic coded
cord through a wall, is that true in the case of power cords for TV's
and computers and things like component cables for DVD players etc..?
Thanks,
Dan

  #5   Report Post  
Posted to alt.home.repair
PipeDown
 
Posts: n/a
Default Running wires...

Damaged wires are more of a shock hazard than a fire hazard but it depends
on the location and kind of abuse.

To have a shock hazard all you need is some bare wire showing. To make that
into a fire hazard, you need that bare wire (actually the hot and ground or
hot and neutral) to come in contact with something moderately resistive so
the current can be turned into lots of heat or have it contact something
metal (low resistive) so that sparks land on combustable materials (before
the breaker trips)

Your plan sounds fine unless the wall is insulated or covered in paneling
such that many nails protrude into the wall cavity. It might be a bit more
asthetic than a hanging wire.

you can get surface mount conduit for that as well. Save you from putting a
hole in the wall but you still have a track on the surface to look at.


wrote in message
oups.com...
I just bought some small reading lights that I'd like to install over
my bed and I was hoping to run the wire (single wire for power) behind
the wall down to a power outlet at the baseboard. My concern is that
the power wire is very thin and I'm wondering if this is a potential
fire hazard; any ideas on that? My overall plan is to drill a small
hole just behind the light and let the wire dangle behind the wall, it
would come out near the baseboard where it will be connected to a surge
protector connected to a standard power outlet. Any issues with that
plan?
Thanks,
Dan





  #6   Report Post  
Posted to alt.home.repair
ameijers
 
Posts: n/a
Default Running wires...


wrote in message
oups.com...
Any good examples of this? I'm looking for the cleanest display I can
get... are there many options of these sleeves?

If you don't want hanging wires, put an old-work box the appropriate
distance off the floor, and either mount an wall reading lamp with the pivot
arms, or a recessed clock outlet that you can tuck the excess cord into, and
hang the lamps you bought from the hanger screw.

Wall mounted bed lamps were dirt-common in the 50s and 60s. Some motels
still have them.

aem sends....

  #7   Report Post  
Posted to alt.home.repair
SQLit
 
Posts: n/a
Default Running wires...


wrote in message
oups.com...
I just bought some small reading lights that I'd like to install over
my bed and I was hoping to run the wire (single wire for power) behind
the wall down to a power outlet at the baseboard. My concern is that
the power wire is very thin and I'm wondering if this is a potential
fire hazard; any ideas on that? My overall plan is to drill a small
hole just behind the light and let the wire dangle behind the wall, it
would come out near the baseboard where it will be connected to a surge
protector connected to a standard power outlet. Any issues with that
plan?
Thanks,
Dan


Is the wire/cord even listed to be covered up? Most are not, they are
intended to be exposed.


  #8   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Running wires...

I doubt this is up to code to be covered so I'll either have to put a
cut in box in or have it exposed. I just wish there were better
options out there for exposed wires, it just looks so much better when
hiddent behind the wall. Any ideas on my other cables like TV power
cables and component cables for satelite receivers and such? I also
have a home entertainment system I'm considering and would like to put
those wires in wall as well... any issues with those "heavier duty"
type cables?

  #9   Report Post  
Posted to alt.home.repair
RBM
 
Posts: n/a
Default Running wires...

offhand I don't know of any, but these are often sold with-for swing arm
fixtures sold at lighting stores. I've seen them in brass and white plastic



wrote in message
oups.com...
Any good examples of this? I'm looking for the cleanest display I can
get... are there many options of these sleeves?



  #10   Report Post  
Posted to alt.home.repair
Don Young
 
Posts: n/a
Default Running wires...

Do not run any flexible cords into wall, ceiling, or floor cavities if you
want your electrical system to be safe and code compliant. Electrical
systems have enough hazards without creating unnecessary ones.

Don Young
wrote in message
oups.com...
I doubt this is up to code to be covered so I'll either have to put a
cut in box in or have it exposed. I just wish there were better
options out there for exposed wires, it just looks so much better when
hiddent behind the wall. Any ideas on my other cables like TV power
cables and component cables for satelite receivers and such? I also
have a home entertainment system I'm considering and would like to put
those wires in wall as well... any issues with those "heavier duty"
type cables?





  #11   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Running wires...

Put a compace florescent bulb in it and there is no fire hazzard.
Rather then run the lamp cord to the basement, run romex to the
bedroom and just put a thin surface mounted box on the exterior of the
baseboard. Then permanently wire it in the basement to the nearest
light or outlet. You wont see the outlet under the bed. This way
it's all legal.

On 21 Mar 2006 16:00:57 -0800, "
wrote:

bed reading lights are severe fire hazards. all that nice fuffy bed
linens close by nice lint that burns easy close by nice hot lights, now
add the light getting bumped

Is this a light that attaches to the bed frame? like headboard?

in any case you should never run plastic covered wires like light cords
thru walls.

they can be damaged easy and start fires fast.

if its a low voltage lamp it MIGHT be ok, but I dont recommend it.

I suggest you return the light.

Of course this after helping a friend and his wife gut their home after
a bed lamp did $130,000 damage to their house


  #12   Report Post  
Posted to alt.home.repair
kevin
 
Posts: n/a
Default Running wires...

I don't understand quite what you are thinking of doing for your "other
cables like TV power cables and component cables...". Your TV has a
plug, right? The plug fits into an outlet on the wall, yes? Were you
thinking of cutting the plug off, running the power cord into the wall,
then splicing it into the home's electrical system? I can't imagine
this is what you are thinking -- it is very very wrong, dangerous, and
seems obviously stupid too (how would you move or unplug the TV for
repairs, cleaning, selling your house, etc?).

If you have mess of wires running from your entertainment center to
outlets and cable TV jacks elsewhere in the room, then you can remedy
it by just installing outlets and cable TV jacks nearer to your
entertainment center. Just install the outlets (or have them installed
by an electrician) directly behind the entertainment center, use some
twisties to bunch up the extra lengths of cords, plug them in, and
forget about them.

As a basic rule of thumb: no cable of any kind should ever pass through
a finished wall (ie. from inside the wall to inside the living space).
Instead, the cable inside the wall always ends at some kind of outlet
or jack mounted on the wall. An exception is half-ass cable TV coaxial
installations, and half-ass phone installations.

As for your nighttime reading lights, either mount a box in the wall
where you want the light to be (using normal romex inside the wall),
fix the light right to the box, and make the connection inside. Or, use
a simple plastic sleeve of some kind to make the dangling cord look
nicer. And in both cases, make sure the light is fixed securely to the
wall.

-Kevin

  #13   Report Post  
Posted to alt.home.repair
No
 
Posts: n/a
Default Running wires...

wrote in message
oups.com...
Thanks for the advise, I think you guys have convinced me to stay away
from this solution and go with the sleeve! Although, one question that
I have from the previous reply: you said to never run a plastic coded
cord through a wall, is that true in the case of power cords for TV's
and computers and things like component cables for DVD players etc..?
Thanks,
Dan


Those types of things are low or no voltage and if done properly the outer
casing of the wire will not give off toxic smoke if burned. Its called
Plenum rated or some such thing. They are fine.

Its the lamp cord with AC electric that should not be used.

See my other reply for another option.


  #14   Report Post  
Posted to alt.home.repair
No
 
Posts: n/a
Default Running wires...

wrote in message
oups.com...
I just bought some small reading lights that I'd like to install over
my bed and I was hoping to run the wire (single wire for power) behind
the wall down to a power outlet at the baseboard. My concern is that
the power wire is very thin and I'm wondering if this is a potential
fire hazard; any ideas on that? My overall plan is to drill a small
hole just behind the light and let the wire dangle behind the wall, it
would come out near the baseboard where it will be connected to a surge
protector connected to a standard power outlet. Any issues with that
plan?
Thanks,
Dan


Dan - The best solution would be to mount the fixture permanently. This
would involve installing a box to mount the fixture on, a wall switch if
desired and running romex wire in the wall from an appropriate connecting
point.

The light you bought may or may not support this type of install. If not,
and you do not just want to plug it in as is, then you may want to get a
different light.

You could also just install an outlet high up on the wall. The electrical
code does not specify the location of the outlets in a room if I remember
correctly.


  #15   Report Post  
Posted to alt.home.repair
Bob M.
 
Posts: n/a
Default Running wires...


wrote in message
oups.com...
Any good examples of this? I'm looking for the cleanest display I can
get... are there many options of these sleeves?


"Wiremold" plastic raceway available at Lowe's, Home Depot, etc. Sticks to
the wall, wires run inside the raceway. Comes in metal too; I used the
metal stuff to mount a ceiling light over the basement steps - attic access
was too difficult.




  #16   Report Post  
Posted to alt.home.repair
Terry
 
Posts: n/a
Default Running wires...


"Bud--" wrote in message
.. .
No wrote:

wrote in message
oups.com...

Thanks for the advise, I think you guys have convinced me to stay away
from this solution and go with the sleeve! Although, one question that
I have from the previous reply: you said to never run a plastic coded
cord through a wall, is that true in the case of power cords for TV's
and computers and things like component cables for DVD players etc..?
Thanks,
Dan

I have to agree with;
"Power cords should never be run through walls, floors, ceilings, drop
ceilings etc."

Note the point being 'power cords'; in this case being the wiring to devices
that can be plugged in to a source of AC voltage (typically in North America
that's 115 volts from a wall outlet; in Europe and elsewhere, perhaps 230
volts).

Signal wiring ........................ snipped ....................
includes phone, loudspeaker, cable, doorbell and various computer signal
cables. These can be run through walls, floors, etc. "Lamp cord" can be
used for these low voltage runs.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Wires Too Short in Outlet Box, How to Extend Length ? BOB Home Repair 19 March 20th 06 02:41 PM
Help in pullng wires through 1/2 inch EMT Ron Home Repair 10 August 24th 04 03:47 PM
A different single-point threading question.... Ken Sterling Metalworking 40 June 3rd 04 03:23 AM
wires to capacitor on YORK AC unit are burned and melted Keith Reding Home Repair 58 February 18th 04 03:38 PM
OT electrical question Ivan Vegvary Metalworking 24 August 1st 03 02:36 AM


All times are GMT +1. The time now is 01:57 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"