  #1   Report Post  
 
Posts: n/a
Default bathroom lighting dillema

I have a bit of a dillema with my bathroom lighting. I am trying to
install a new light above the mirror but i just can't seem to get it to
hook up properly. The existing light worked and I was positive I saw
what was already hooked up and did the same with the new light. I have
black to black and white to white, but still nothing works. The concern
that I have, and which is more than likely the case, is that I am
attaching the wrong wires. There are three sets of black and white
wires comig out from the back of the lighting panel. If you picture the
octagonal box facing you there are to sets of wires on the far left
(which is closest to the wall with the light switch) one above the
other, and then the last set of black and white wires are located down
towards the bottom right corner of the oct. box. THe white wire from
the bottom right one is left open whereas the other white wires have
been merretted together. My problem lies with the black wires. Since
there are three of them exposed I have tried connecting the black wire
from the new light to each one of them and still no luck with power. I
hope I have explained everything ok, if not I will try to give as much
clarification as possible if anyone is willing to help.

=)
cheers

  #2   Report Post  
RBM
 
Posts: n/a
Default bathroom lighting dillema

If this is the only light that goes on with the switch, what you have in the
box are one feed, bringing in the 120? volts, one line bringing the 120?
volts out to something else, and one cable which goes to your switch. Once
you determine which is which, you should have two white wires together which
will also connect to the white of your fixture. You'll have two blacks
together to which you will also attach the white wire to your switch and
wirenut the three. You are left with one black, which is the return wire
from the switch and this will go to the black of your fixture.




wrote in message
oups.com...
I have a bit of a dillema with my bathroom lighting. I am trying to
install a new light above the mirror but i just can't seem to get it to
hook up properly. The existing light worked and I was positive I saw
what was already hooked up and did the same with the new light. I have
black to black and white to white, but still nothing works. The concern
that I have, and which is more than likely the case, is that I am
attaching the wrong wires. There are three sets of black and white
wires comig out from the back of the lighting panel. If you picture the
octagonal box facing you there are to sets of wires on the far left
(which is closest to the wall with the light switch) one above the
other, and then the last set of black and white wires are located down
towards the bottom right corner of the oct. box. THe white wire from
the bottom right one is left open whereas the other white wires have
been merretted together. My problem lies with the black wires. Since
there are three of them exposed I have tried connecting the black wire
from the new light to each one of them and still no luck with power. I
hope I have explained everything ok, if not I will try to give as much
clarification as possible if anyone is willing to help.

=)
cheers



  #3   Report Post  
 
Posts: n/a
Default bathroom lighting dillema

hmmm, I understand your explanation regarding the wires I am just
wondering how I can determine which are for which. Beside the light
switch on the same wall there is also a plug, would this account for
one of the sets of wires as well?

Also, is there any guaranteed way of ensuring the wires stay connected?
By this I mean is there any product out there that will ensure a more
secure conenction between the wires that you are using. THe reason for
my question is that merrets (wire connectors) just seem to be so darn
tempermental. Just when you think you've got the wires secured together
you go and try and tuck them away and one wire pops out.

In the response you gave it seems like I will definitely be connecting
two or more copper wires together, using a bigger wire connector
(merrett) would definitely be the better way to go then eh?

thanks for your help so far.

cheers

  #4   Report Post  
Rich Greenberg
 
Posts: n/a
Default bathroom lighting dillema

In article .com,
wrote:
I have a bit of a dillema with my bathroom lighting. I am trying to
install a new light above the mirror but i just can't seem to get it to
hook up properly. The existing light worked and I was positive I saw
what was already hooked up and did the same with the new light. I have
black to black and white to white, but still nothing works. The concern
that I have, and which is more than likely the case, is that I am
attaching the wrong wires. There are three sets of black and white
wires comig out from the back of the lighting panel. If you picture the
octagonal box facing you there are to sets of wires on the far left
(which is closest to the wall with the light switch) one above the
other, and then the last set of black and white wires are located down
towards the bottom right corner of the oct. box. THe white wire from
the bottom right one is left open whereas the other white wires have
been merretted together. My problem lies with the black wires. Since
there are three of them exposed I have tried connecting the black wire
from the new light to each one of them and still no luck with power. I
hope I have explained everything ok, if not I will try to give as much
clarification as possible if anyone is willing to help.


Here is my best guess:

The 3 b/w pairs a
1) Supply from the breaker.
2) The switch.
3) feed to some other light or fan.

Seperate all wires. See if one pair has 110vac on it. Thats #1.

If the other 2 pairs have zero voltage between then and to ground, then
use an ohmmeter (or continuity tester). If one goes from zero ohms to
infinite ohms with flipping the switch, Thats #2.

If the third pair has continuity independant of the switch and is some
value greater than zero ohms, thats (probably) #3.

Turn the breaker off. Connect the #1 & #3 pairs together, black to
black and white to white. Turn the breaker on. Is another light or a
fan now on? If yes, your rolling. Turn the breaker off again.

Disconnect the temporary connection between #1 & #3. Connect #3 to the
light fixture matching colors.

Connect the white wire of #1 to the white of the fixture & #3.

Connect the black wire of #1 to the black of #2.

Connect the white of #2 to the black of the fixture & #3.

Check the wireing, turn switch off. Turn breaker on. If my guesses are
correct and you did it right all should work.

If it turns out that you did NOT want whatever is on #3 to be controlled
by the switch but on always (perhaps it has its own switch), move the
black & white of #3 from the b/w of the fixture to the b/w of #1.

Put everything back together and clean up.

NOTE: If you are not comfortable doing the tests and connections I have
described, CALL AN ELECTRICIAN.

--
Rich Greenberg Marietta, GA, USA richgr atsign panix.com + 1 770 321 6507
Eastern time. N6LRT I speak for myself & my dogs only. VM'er since CP-67
Canines:Val, Red & Shasta (RIP),Red, husky Owner:Chinook-L
Atlanta Siberian Husky Rescue. www.panix.com/~richgr/ Asst Owner:Sibernet-L
  #5   Report Post  
 
Posts: n/a
Default bathroom lighting dillema

I have taken a picture of the box and the wires in the hopes that some
clarification will arise regarding my dillema. Thanks for your
detailed description regarding some steps I should take. I will give
them a shot and see how they turn out. But let me know if the picture
makes any thing clearer.

thanks

http://ca.geocities.com/mybrainhurts...mages/pic1.jpg

cheers



  #7   Report Post  
Mikepier
 
Posts: n/a
Default bathroom lighting dillema

The link to the pictures did not work. But one thing that I do not
think was mentioned, if you have GFI outlet in your bathroom, see if
you have to reset it.

  #8   Report Post  
Don Klipstein
 
Posts: n/a
Default bathroom lighting dillema

In article .com,
wrote:
I have a bit of a dillema with my bathroom lighting. I am trying to
install a new light above the mirror but i just can't seem to get it to
hook up properly. The existing light worked and I was positive I saw
what was already hooked up and did the same with the new light. I have
black to black and white to white, but still nothing works. The concern
that I have, and which is more than likely the case, is that I am
attaching the wrong wires. There are three sets of black and white
wires comig out from the back of the lighting panel. If you picture the
octagonal box facing you there are to sets of wires on the far left
(which is closest to the wall with the light switch) one above the
other, and then the last set of black and white wires are located down
towards the bottom right corner of the oct. box. THe white wire from
the bottom right one is left open whereas the other white wires have
been merretted together. My problem lies with the black wires. Since
there are three of them exposed I have tried connecting the black wire
from the new light to each one of them and still no luck with power.


There are now 9 combinations to try, and it is still possible to
overload a white wire somewhere in your house if you use a white wire
other than the one associated with the proper black wire (assuming more
than one white wire works).

If any wires are of color other than what is usually used (sometimes
indicating a hot-neutral reverse - I do see this sometimes), it gets even
more complicated. You will need a multimeter to identify hot, grounded
(neutral), and not-connected-to-anything wires. Hot wires have close to
120V with respect to ground. Neutral wires have no voltage with respect
to ground, except can have a little if current from something else
flows through a part of that circuit. Neutral wires have close to 120V
with respect to hot wires. Wires not connected to anything ideally have
no voltage with respect to either hot wires or ground, although you
usually get some low voltage readings with respect to hot, ground, or
both.

Anyone else doing such a job in the future, when seeing wires going
nowhere of same color as wires being disconnected, should put tape or some
other marking on the wires that were used.

===================

Is the new fixture fluorescent? If so, you need a ground wire going to
the green wire in the fixture or to the metal fixture frame. Using the
neutral for this will work but feels to me like a code violation and
probably increases the risk of a shock hazard from wire or connection
failures.
Fluorescent bulbs trying to start can have the electric field
distribution within the bulbs affected by grounding of the fixture. This
sometimes (not always) affects starting of fluorescents.

- Don Klipstein )
  #9   Report Post  
Don Klipstein
 
Posts: n/a
Default bathroom lighting dillema

In article .com,
wrote:

Also, is there any guaranteed way of ensuring the wires stay connected?
By this I mean is there any product out there that will ensure a more
secure conenction between the wires that you are using. THe reason for
my question is that merrets (wire connectors) just seem to be so darn
tempermental. Just when you think you've got the wires secured together
you go and try and tuck them away and one wire pops out.

In the response you gave it seems like I will definitely be connecting
two or more copper wires together, using a bigger wire connector
(merrett) would definitely be the better way to go then eh?


Try wirenuts of a different size. They come in different sizes and
should have ratings as to how many wires of what size.

You may have to straighten and retwist wires. Retwist them with pliers.
Twist them in the same direction that the wirenut rotates when putting on
the wirenut.
You may need to gain experience as to how tightly to put on a wirenut.
Get a few spare wirenuts and a few feetb of Romes of same wire size to
practice on if you are new to this.

I have at a few times found wire ends screwed up beyond usefulness, and
then had to cut the wires and strip them to expose fresh wire ends to
twist.

Also, it is a good idea to use electrical tape to tape on the wirenuts
once they are on. Wind on at least a couple layers of tape around both
the wirenut and the wires being capped. This helps the wirenut not get
dislodged by bending of the wires afterwards or by shock/vibration.

- Don Klipstein )
  #10   Report Post  
 
Posts: n/a
Default bathroom lighting dillema

i do have gfi outlet and I will try and do the whole reset thing. In
regards to the link to the picture you have to click the little blue
line before the @rogers.com part because it is protecting my email addy
from spammers and stuff.

cheers



  #11   Report Post  
 
Posts: n/a
Default bathroom lighting dillema

i just went and checked the GFI plug and nothing was tripped. I guess
since it is 12:30am I will head to bed and have to go out and buy a
voltmeter tomorrow and try and get this all figured out.

  #12   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default bathroom lighting dillema

I just wanted to say thanks to everyone for their input and assistance.
I got myself the digital multi meter, found out what was what, and
hooked everything up properly. And voila...let there be light!!

Thanks again

  #13   Report Post  
Posted to alt.home.repair
nospambob
 
Posts: n/a
Default bathroom lighting dillema

Wish more would post what they did to solve the reason for original
post! Thanks.

On 29 Nov 2005 10:22:18 -0800, wrote:

I just wanted to say thanks to everyone for their input and assistance.
I got myself the digital multi meter, found out what was what, and
hooked everything up properly. And voila...let there be light!!

Thanks again

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
bathroom lighting frank spencer UK diy 0 May 16th 05 12:54 PM
bathroom lighting electrics question Ray Holden UK diy 1 February 19th 04 09:25 AM
Advice on bathroom lighting in shallow false ceiling [email protected] UK diy 8 October 28th 03 05:54 PM
bathroom lighting - IP65? IP44? IP20? rob c UK diy 1 September 28th 03 04:46 PM
Halogen Lighting in Bathroom Ian Clarke UK diy 15 August 1st 03 10:25 AM