How To Drain and Refill Boiler
I have a Peerless WV3 boiler as my heating system with an embedded coil for domestic hot water. Can somebody point me to instrux on proper drainage and refilling ? Thanks. |
#2
|
|||
|
|||
On Sat, 10 Sep 2005 22:01:55 GMT, Vince
wrote: I have a Peerless WV3 boiler as my heating system with an embedded coil for domestic hot water. Can somebody point me to instrux on proper drainage and refilling ? Thanks. Is this a hot-water heating system? If so routine draining is not recommended and serves only to introduce oxygen into the system which causes rust. I recommend that you go to www.heatinghelp.com and find out more than you probably really want to know about your type heating system. Dan |
#3
|
|||
|
|||
"Vince" wrote in message ... I have a Peerless WV3 boiler as my heating system with an embedded coil for domestic hot water. Can somebody point me to instrux on proper drainage and refilling ? Thanks. Dan made a good point, but I need to ask one simple question. Why do you want (or need to) drain the boiler? |
#4
|
|||
|
|||
On Sun, 11 Sep 2005 00:07:19 -0400, "HeatMan"
wrote: "Vince" wrote in message .. . I have a Peerless WV3 boiler as my heating system with an embedded coil for domestic hot water. Can somebody point me to instrux on proper drainage and refilling ? Thanks. Dan made a good point, but I need to ask one simple question. Why do you want (or need to) drain the boiler? Need to drain boiler (or Lower the water level ???) so that a baseboard heater element may be replaced. |
#5
|
|||
|
|||
On Sat, 10 Sep 2005 23:30:11 GMT, Dan wrote:
On Sat, 10 Sep 2005 22:01:55 GMT, Vince wrote: I have a Peerless WV3 boiler as my heating system with an embedded coil for domestic hot water. Can somebody point me to instrux on proper drainage and refilling ? Thanks. Is this a hot-water heating system? If so routine draining is not recommended and serves only to introduce oxygen into the system which causes rust. I recommend that you go to www.heatinghelp.com and find out more than you probably really want to know about your type heating system. Dan Hi Dan: Yes, ho****er heating. Thanks. |
#6
|
|||
|
|||
"Vince" wrote in message Need to drain boiler (or Lower the water level ???) so that a baseboard heater element may be replaced. There should be a valve or two on the boiler that you can open. Shut off the feed first, then open the drain valve. It does not have to be 100% empty, just enough that you can replace the baseboard. It will fill itself after you open the feed, but you may have to bleed off some air. Some heating systems have automatic valves for that. |
#7
|
|||
|
|||
On Sun, 11 Sep 2005 05:03:16 GMT, "Edwin Pawlowski"
wrote: "Vince" wrote in message Need to drain boiler (or Lower the water level ???) so that a baseboard heater element may be replaced. There should be a valve or two on the boiler that you can open. Shut off the feed first, then open the drain valve. It does not have to be 100% empty, just enough that you can replace the baseboard. It will fill itself after you open the feed, but you may have to bleed off some air. Some heating systems have automatic valves for that. Thanks Ed: When you refer to the "feed", is that meant to be the main feed control for the entire house ? There is a control valve between the cold water feed line and the pressure regulator, which is followed by an air bleed valve. I think that is the valve for me to use, or should I use the house main water feed shut off control valce that is above (follows) the water meter ? I will also shut down the electrical power to the heating system while I have located the drain valve; it has a fitting for attaching a garden hose to it. I can route the drain water to a nearby drywell drain located outside my basement door. There is a second hose spicket/valce located at the base of the boiler cabinet. I don't think that is the valve to use when draining, as there is no need to drain water from the boiler itself. OK? There is a shut off valve in the return path also, between the drain valve and the water circulator pump. I dont know if that valve must be closed or left as is ? I've just taken some digital pics, and can upload those for viewing at epson photo website, if needed. Thanks again for your info, Ed. |
#8
|
|||
|
|||
"Vince" wrote in message When you refer to the "feed", is that meant to be the main feed control for the entire house ? There is a control valve between the cold water feed line and the pressure regulator, which is followed by an air bleed valve. I think that is the valve for me to use, or should I use the house main water feed shut off control valce that is above (follows) the water meter ? No need to shut off the house. Thee should be a valve either on or just before the boiler to shut off the feed into it. I will also shut down the electrical power to the heating system while Yes, I should have mentioned that. You don't want it to fire when water is low. I have located the drain valve; it has a fitting for attaching a garden hose to it. I can route the drain water to a nearby drywell drain located outside my basement door. That's the one. You won't get a lot out of it. There is a second hose spicket/valce located at the base of the boiler cabinet. I don't think that is the valve to use when draining, as there is no need to drain water from the boiler itself. OK? Correct. As long as the line you are working on is drained yo are good to go. There is a shut off valve in the return path also, between the drain valve and the water circulator pump. I dont know if that valve must be closed or left as is ? You should not need it. I've just taken some digital pics, and can upload those for viewing at epson photo website, if needed. Thanks again for your info, Ed. If you are still unsure,, go ahead, but I think you have the right idea. You're welcome. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
New condensing boiler installation - truth or lies | UK diy | |||
Low DHW temperature from combi boiler | UK diy | |||
Easy drain central heating | UK diy | |||
Cleaning/Flushing a pressurise ad sealed CH system | UK diy | |||
Flushing and treating Central Heating question | UK diy |