Default Basement Humidity

I am currently finishing 75 % of my basement area. The remainder of the
area will remain unifinished (all the mechanicals and some storage). The
foundation is block and I do have a sump pump so things are dry. As a last
step in the project I plan to install carpet. I do have a decent size
dehumidifier to keep the moisture level down. Is there a humidity threshold
that I should stay at or below to avoid the musty smell that could develop
over time? My house is 7 years old and I do have Central Air. However,
there are no cold air return vents in the basement.

Thanks,
-a12vman



  #2   Report Post  
Buck Turgidson
 
Posts: n/a
Default

I am currently finishing 75 % of my basement area. The remainder of
the
area will remain unifinished (all the mechanicals and some storage).

The
foundation is block and I do have a sump pump so things are dry. As a

last
step in the project I plan to install carpet. I do have a decent size
dehumidifier to keep the moisture level down. Is there a humidity

threshold
that I should stay at or below to avoid the musty smell that could

develop
over time? My house is 7 years old and I do have Central Air.

However,
there are no cold air return vents in the basement.


You say that you are finishing your basement, and there are no cold air
returns. I assume you have or are adding vents for A/C and heat, right?
If they're at floor level, as opposed to in the ceiling, and if the air
can return upstairs (no closed doors), that should help.

Since your mechanicals are there, it shouldn't be hard to add an air
return.


  #3   Report Post  
m Ransley
 
Posts: n/a
Default

Sealing walls and floors with oil paint will help keep moisture from
entering. But any leaks or dampness will develop mold behind walls. This
is where a moisture meter is necessary to pinpoint bad areas. I keep my
basement around 50-60%. If you smell mustiness it is mold even if you
don`t see it. If so then killing it with bleach is a good first step,
even spaying the walls with a grden sprayer. Test the floor tape plastic
to it maybe several ft square if moisture collects you have to fix it
first or the carpet will mold. Under carpet consider plastic sheet, it
is better than ruining carpet. Cutting in an adjustable-closeable return
is good for summer to move moist air out and a closeable supply for
winter. It is easier to find and fix problems now instead of later.

  #4   Report Post  
Joseph Meehan
 
Posts: n/a
Default

a12vman wrote:
I am currently finishing 75 % of my basement area. The remainder of
the area will remain unifinished (all the mechanicals and some
storage). The foundation is block and I do have a sump pump so
things are dry. As a last step in the project I plan to install
carpet. I do have a decent size dehumidifier to keep the moisture
level down. Is there a humidity threshold that I should stay at or
below to avoid the musty smell that could develop over time? My house
is 7 years old and I do have Central Air. However, there are no cold
air return vents in the basement.

Thanks,
-a12vman


I would want that 75% (how are you measuring this?) down to no more than
60% at any time. I would suggest you likely need more ventilation. I
suggest you have a HVAC professional come out and do the numbers (Manual D)
to see what should be done.


--
Joseph Meehan

Dia's Muire duit


  #5   Report Post  
Mark
 
Posts: n/a
Default

agreed, you need a vapor barrier on the floor of some kind

either waterproof paint or plastic

Mark



  #6   Report Post  
pgg
 
Posts: n/a
Default

On Mon, 11 Apr 2005 13:54:10 -0700, Mark wrote:

agreed, you need a vapor barrier on the floor of some kind

either waterproof paint or plastic


Here in Wisconsin, most carpet in basements are installed _without_
waterproof paint or plastic. I called many many places for
recommendations and they all said that carpet directly over the slab is
the best way to go because any vapor emission is vented through the carpet
instead of getting trapped behind plastic causing mold to grow under the
plastic.

I was surprised too. My brother-in-law paid lots of money for a
professional contractor to finish his basement and carpet was laid
directly on the slab.

  #7   Report Post  
stretch
 
Posts: n/a
Default

Buck

The method depends on your local conditions. It would help if you said
where you are located. Mold starts to grow at about 80%. 75% RH is
too high. If there is a cold spot in the room, it will grow mold
because the RH will be higher there. Keep the Relative Humidity (RH)
40 to 60 %. Mold is more likely to grow on surfaces where AC blows
directly on it.

Stretch

  #8   Report Post  
a12vman
 
Posts: n/a
Default

I currently have 4 Ceiling Mount supply vents and no returns. The Returns
runs right alongside the supply trunk(right down the middle of the house) so
does it make sense to have the cold air returns that close to the supply
vents?


"Buck Turgidson" wrote in message
...
I am currently finishing 75 % of my basement area. The remainder of

the
area will remain unifinished (all the mechanicals and some storage).

The
foundation is block and I do have a sump pump so things are dry. As a

last
step in the project I plan to install carpet. I do have a decent size
dehumidifier to keep the moisture level down. Is there a humidity

threshold
that I should stay at or below to avoid the musty smell that could

develop
over time? My house is 7 years old and I do have Central Air.

However,
there are no cold air return vents in the basement.


You say that you are finishing your basement, and there are no cold air
returns. I assume you have or are adding vents for A/C and heat, right?
If they're at floor level, as opposed to in the ceiling, and if the air
can return upstairs (no closed doors), that should help.

Since your mechanicals are there, it shouldn't be hard to add an air
return.




  #9   Report Post  
m Ransley
 
Posts: n/a
Default

Is furnace on basement floor, it is a upflow unit with return on bottom?
Just cut in a return at the lowest point. mine is 4" from the floor. A
10 min job.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Best way to finish outside basement door Fr@nk Home Repair 0 April 2nd 05 10:54 PM
Mudroom in basement - need your suggestion FGreen Home Repair 5 July 6th 04 10:40 PM
Advice needed on new basement - sump hole higher than rest of basement Doug Swetland Home Ownership 1 September 24th 03 06:09 PM
Advice needed on new basement - sump hole higher than rest of basement Brad Home Ownership 1 September 24th 03 05:51 PM
Floor choice for walkout basement? FC Home Ownership 0 July 1st 03 03:28 PM


All times are GMT +1. The time now is 07:24 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"