Recently opened up a 120v,60hz Coffee machine, and the pump has a large
diode in series with one of its 120v input leads. The pump works either with
this diode, or without. Just wondering why its there?

Thanks
--
Kim..."A Man Of True Frankenstinean Proportions"

--
Kim..."A Man Of True Frankenstinean Proportions"


  #2   Report Post  
Shawn D'Alimonte
 
Posts: n/a
Default

Kim Sleep wrote:
Recently opened up a 120v,60hz Coffee machine, and the pump has a large
diode in series with one of its 120v input leads. The pump works either with
this diode, or without. Just wondering why its there?


That is probably the thermal cut-out. It turns off the power if the
machine overheats. Do not bypass this - If it is open then the machine
overheated and will likely do so again. Without that part the machine
could melt or catch fire. If you must try to fix it get a proper
replacement part.

BTW Most coffee makers do not have pumps. The boiling water forces it
through the pipe. I assume this part is attached to the bottom of the
heater.
  #3   Report Post  
Bob Shuman
 
Posts: n/a
Default

Are you sure it is a diode? I'd bet it is a thermal fuse. You can tell by
the thermal rating and current limit rating which is usually stamped on the
body. Another way to check is to use a continuity/diode tester. A diode
will only conduct in one direction with a small ~(0.7V) drop while the fuse,
if still good, will look like a dead short in both directions.

The fuse is a safety device to prevent overheating and the device from
catching fire.

Bob


"Kim Sleep" wrote in message
.. .

Recently opened up a 120v,60hz Coffee machine, and the pump has a large
diode in series with one of its 120v input leads. The pump works either

with
this diode, or without. Just wondering why its there?

Thanks
--
Kim..."A Man Of True Frankenstinean Proportions"

--
Kim..."A Man Of True Frankenstinean Proportions"




  #4   Report Post  
Jerry G.
 
Posts: n/a
Default

This sounds like the thermo fuse. If it needs replacement, contact the
manufacture rep, or a service centre for your pump to have the correct
replacement. If it blows again, then the pump, or something along its chain
of operating also needs replacement. If you bypass the thermo fuse, and
there is a fault, the result can lead to a burned motor, or worse.

--

Jerry G.
=====

"Kim Sleep" wrote in message
.. .

Recently opened up a 120v,60hz Coffee machine, and the pump has a large
diode in series with one of its 120v input leads. The pump works either with
this diode, or without. Just wondering why its there?

Thanks
--
Kim..."A Man Of True Frankenstinean Proportions"

--
Kim..."A Man Of True Frankenstinean Proportions"



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Sump Pump Help Needed [email protected] Home Repair 14 April 25th 05 05:09 PM
Submersible Pump Overloading in Cold Weather Mark & Mary Ann Weiss Electronics Repair 16 January 26th 05 06:28 PM
Well pump question BGBevill Home Repair 9 October 5th 04 04:29 PM
Water Pump / Pressure Tank Problem !!!!!! James Nipper Home Repair 9 June 28th 04 02:13 AM
Heat pump thermostat question Michael Baugh Home Repair 6 January 26th 04 07:50 AM


All times are GMT +1. The time now is 10:55 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"