TEK 465
Can anyone give me a hint as to why my 465 is dead,no fan,no HV,,,I've
repaired about 2500 crt monitors and around a couple dozen lcd's,,,just a clue anyone??done checked fuses,,, is there three or four???(just in case)...... DMM on top works fine. Many,many,many, thanks Joe Smith West Point Monitor Repair |
#2
Posted to sci.electronics.repair
|
|||
|
|||
TEK 465
|
#3
Posted to sci.electronics.repair
|
|||
|
|||
TEK 465
Can anyone give me a hint as to why my 465 is dead,no fan,no HV,,,I've
repaired about 2500 crt monitors and around a couple dozen lcd's,,,just a clue anyone??done checked fuses,,, is there three or four???(just in case)...... The commonest problem with 465 and similar Tek scopes seems to be power supply failure, due to shorted solid-tantalum capacitors, or dried-up (high-ESR or open) electrolytic cans. http://www.repairfaq.org/sam/tshoot.htm#tshsco is a good place to start reading. -- Dave Platt AE6EO Friends of Jade Warrior home page: http://www.radagast.org/jade-warrior I do _not_ wish to receive unsolicited commercial email, and I will boycott any company which has the gall to send me such ads! |