Default Electric fence "Electric Shepherd" ESB 250


Before wasting time on this, de-rivetting the step up transformer mounting
etc.
Input side measures 5Mohm, HV output side 12.7R, but looks like a standard
mains transformer.
Would this be a purpose wound transformer or an off the shelf mains
transformer that could be replaced with similar, if so what sort of voltages
and which way round ?


--
Diverse Devices, Southampton, England
electronic hints and repair briefs , schematics/manuals list on
http://home.graffiti.net/diverse:graffiti.net/